User's Manual

LTE Outdoor CPE12000 | User Manual 17
Connecting the Cables
Outdoor Connection: Connect a grounding cable between the Ground terminal of the LTE
outdoor CPE and a good ground connection
Preparing and connecting the cable: Use only UTP-FTP 4x2x24AWG CAT. 5E outdoor cable from
an approved manufacturer. The cable provides pin-to-pin connection on both ends
1. Prepare the cable: Use a crimp too for RJ-45 connectors to prepare the wires. Insert them
into the appropriate pins and use the tool to crimp the connector. Make sure to do the
following:
Remove as small a length as possible of the external jacket. Verify that the external
jacket is well inside the sealing cover when connected to the unit, to ensure good
sealing.
Pull back the shield drain wire before inserting the cable into the RJ-45 connector, to
ensure a good connection with the connectors shield after crimping.
The following figure shows the required wire pair connections. The color codes used in
standard cables supplied by the manufacturer are as listed in the table.