3.5 eNB Settings
3.5.1 Preferred eNB
When enable this option operator can “force” UE to attach to specific eNB (up to 8) with priority, in
this way UE ignores its RF signal quality and is attached according to the configuration (MCC, MNC,
ECI).
When UE is count not attached to any eNB in Preferred eNBs list, UE will attach to any other eNB
with higher RF signal quality.
3.5.2 Lock ND&S
When selecting this option UE will attached only to eNB according to configuration (MCC, MNC, ECI).
3.5.3 Auto Rescan duration
When configuring this parameter, UE will drop RF signal after the configurable time interval and
perform re-scanning of available eNBs according to Frequency Configuration and eNB settings.