User Manual
134
Field name
Sample
Explanation
1.
Enable
Enable/Disable
Enable this output rule
2.
Output
Digital OC output
Specify the output type
3.
Action
On / Off
Specify the action to be taken
4.
Action timeout
Enabled / Disabled
Enable timeout for this rule
5.
Timeout (sec)
10
Specifies after how much time this action should end.
6.
Mode
Fixed / Interval
Specify the mode of output activation
7.
Hours
15
Specify the hour for rule activation
8.
Minutes
25
Specify the minute for rule activation
9.
Days
Monday
Select the week days for rule activation
8.12.4.5 Scheduler
This function allows you to set up the periodical, hourly schedule for the outputs. You can select on which week