9 ELECTRICAL INTEGRATION
The following table defines the required electrical conditions:
The TRM-300 auxiliary connector contains the power supply connector (DC-jack) and the I/O connector. It is
an AVX semicustom socket connector (model 58-9157-019-000-094S) with the pin-out according to the
following table and drawing. The application mating I/O connector would be an AVX semicustom plug (or the
model 58-9157-019-000-085 SMT plug along with any standard cover 30-9157-9700-00-xxx; or the model 58-
9157-019-000-086 SMT right angle plug).
N
Name
I/O
Electrical interface
Description
1
GND
---
0 v
Ground
2
UART1.TX
O
Digital 0 3.3 v
UART Tx
3
UART1.RTS
I
Digital 0 3.3 v
UART RTS
4
UART1.DCD
O
Digital 0 3.3 v
UART DCD
5
UART1.RX
I
Digital 0 3.3 v
UART Rx
6
UART1.CTS
O
Digital 0 3.3 v
UART CTS
7
UART1.DTR
I
Digital 0 3.3 v
UART DTR
8
GPS.LOGGER
O
Digital 0 3.3 v
GPS data
9
POWER_OUT
O
Analog 0 7.4 v, I < 250 mA
Power controlled output
10
SW_ON_OFF
I
Digital 0 3.3 v
Switch on/off
They are internally connected
11
SW_ON_OFF
I
Digital 0 3.3 v
12
SIG_IN
I
Digital 0 3.3 v
HiZ, look it up in 9.3.2
Digital input signal
13
SIG_OUT
O
Digital 0 3.3 v
Open colector, look it up 9.3.2
Digital output signal
14
EXTPCM_FS
O
Digital 0 3.3 v
Audio PCM frame sync
15
EXTPCM_DX
O
Digital 0 3.3 v
Audio PCM transmit data
16
EXTPCM_DR
I
Digital 0 3.3 v
Audio PCM receive data
17
EXTPCM_CLK
O
Digital 0 3.3 v
Audio PCM transmit clock,
512 KHz
18
ID_BOTTOM
I
Analog 0 to 3.3 v,
47KΩ pull-up to 3.3 v internally
Accessory detector
19
GND
---
0 v
Ground
20
GND
---
0 v
Ground
21
DC_IN
I
6.3 to 8.4 v, nominal value = 7.4 v
I < 3.5 A
Power supply
22
GND
---
0 v
Ground
Parameter
Specification Limit
Operating supply voltage
From 6.3V up to 8.4V (7.4V nominal)
Supply current
Up to 3.5A of peak value