User's Manual

BSR75 USER AND
INSTALLATION
MANUAL
Code: D198N61_DDS06
Date: 15/07/09 Page: 15 of 16
01.01.00/1 Rev.1
RTX75
ON OFF
Internal power supply failure. Contact Technical
services.
REF. ERROR
ON
Failure in the 10MHz reference. Contact Technical
services.
INT. ERROR ON Internal failure. Contact Technical services.
BBSR
ERROR
ON
Communication failure with the RCPU module. Check
that all the modules are correctly installed. Contact
Technical services if still unsolved.
RPA75
ERROR
ON
Failure in the RPA75 modules. Check that the RF SMB
cables (Ref. 10) are properly connected. Contact
Technical services if still unsolved.
RPW ERROR
ON
Reflected power alarm. Check that the antenna is
properly installed. Contact Technical services.
RRX
ON OFF
Internal power supply failure. Contact Technical
services.
REF. ERROR
ON
Failure in the 10MHz reference. Contact Technical
services.
INT. ERROR ON Internal failure. Contact Technical services.
BBSR
ERROR
ON
Communication failure with the RCPU module. Check
that all the modules are correctly installed. Contact
Technical Services if still unsolved.
BSYNC
ON OFF
Internal power supply failure. Contact Technical
services.
REF. ERROR
ON
Failure in the 10MHz reference. Contact Technical
services.
TIME GPS ON
If GPS is activated, there is failure in the data frame.
Contact Technical Services.
PPS GPS OFF
If GPS is activated, there is failure in the PPS signal of
the GPS:
- check that the starting up period has been
exceeded (about 10 minutes after switching on)
- check the GPS antenna connection.
- check the correct positioning of the GPS
antenna, in accordance with the manufacturer’s
instructions.
Contact technical services if still unsolved.
TIME LOCAL OFF
If GPS is not activated, there is failure in the local
reference data frame. Contact Technical Services.
PPS LOCAL OFF
If GPS is not activated, there is failure in the local PPS
signal. Contact Technical Services.