User's Manual
Page 17
6 Series 90 Specifications
Performance Specifications
Output Voltage (Nominal) Nominally 24V 5%
Output Current (Nominal) Rated from 0 – 50 mA
Load Regulation 0.5% from a 30 mA load
Ripple 50 mV Peak-to-Peak
Output Short Circuit Protection Output is current limited to 50 mA
Accuracy ± 1% of Span – dependent on Sensor Spec.
Hardware Specifications
Sensor Assemblies Differential Pressure measurement type.
Housing Weatherproof; UL recognized (UL94V-0); flame-retardant
glass-filled nylon or Polypropylene or Stainless Steel
Unit Gross Weight Without Sensor Assembly: 2.0 lbs. (0.91 kg)
Battery
Type 6V – Approved TankLink Battery Pack, P/N 394-00010.
Expected Battery Life One call out per day – up to 20 months
Three call outs per day – up to 14 months.
Up to three years for Clients
Environment
Storage Temperature Range -40˚F to 185˚F (-40˚C to 85˚C)
Operating Temperature Range -4˚F to 104˚F (-20˚C to 40˚C)
Cellular Specifications
Type GSM – 3G
Frequency 850 (824 – 894) MHz and
1950 (1850 – 1990) MHz