A. Introduction
G. Maintenence
H. Specification
B. Warning & Cautions
21 3
5 64
D. Emissivity
F. LCD display & buttons
E. Operation
2.
(figure 2)
Diagram description
C. Distance to spot size
This infrared thermometer is used for measuring the tem-
perature of the object's surface, which is applicable for va-
rious hot, hazardous or hard-toreach objects without contact
safe and quickly.
This unit consist of Optics, Temperature Sensor Signal
amplifier, Processing circuit and LCD Display. The Optics
collected the infrared energy emitted by object and focus
onto the Sensor. Then the sensor translates the energy into
an electricity signal. This signal will be turned out to be digital
shown on the LCD after the signal amplifier and processing
circuit.
Equipped with USB data export function, this
product is surely to be a great help to your work.
1. Warning:
To avoid the potential situation may cause harm or dam-
age to people, please pay attention to the following items:
1) . Do not point laser directly at eye or indirectly off reflective
surfaces.
2) . The unit cannot measure through transparent surfaces
such as glass or plastic. It will measure the surface tem-
perature of these materials instead.
3) . Steam, dust, smoke, or other particles can prevent acc-
urate measurement by obstructing by the units optics.
2. Cautions:
Infrared thermometer should be protected for the
following:
1). EMF (electro-magnetic fields) from arc welders,
induction heaters.
2). Thermal shock (cause by large or abrupt ambient
temperature changes allow 30 minutes for unit to
stabilize before use).
3). Do not leave the unit on or near objects of high
temperature.
Emissivity: Most organic materials and painted or
oxidized surfaces have an emissivity of 0.95(preset in
the unit). Inaccurate readings will result from measuring
shiny or polished metal surfaces. To compensate for
this, adjust the units emissivity reading or cover the
surface to be measured with masking tape or flat black
paint. Measure the tape or painted surface when the
tape or painted reach the same temperature as the
material underneath.
1. When take measurement, pay attention to the Distance to
Spot Size. As the Distance (D) from the target surface
increases, the spot size (S) of the area measured by the
unit becomes larger.
The Distance to Spot size of the unit is 20:1.
This unit is equipped with a laser, which is used for aiming.
2. Field of view:
Make sure the target is larger than the unit's spot size. The
smaller the target the closer measure distance. When
accuracy is critical, make sure the target is at least twice as
large as the spot size.
0.30
0.95
0.95
0.70
0.50
0.90
0.85
0.95
0.95
0.95
0.94
0.90
0.93
0.85
0.98
0.70
0.50
0.98
0.94
0.93
0.95
0.95
0.95
0.90
0.98
0.90
0.80
0.94
0.93
0.94
Emissivity
Emissivity
Marterial
Marterial
Aluminum
Asbestos
Asphalt
Basalt
Brass
Brick
Carbon
Ceramic
Concrete
Copper
Dirt
Frozen food
Hot food
Glass(plate)
Ice
Iron
Lead
Limestone
Oil
Paint
Paper
Plastic
Rubber
Sand
Skin
Snow
Steel
Textiles
Water
Wood
1. Operating the unit
1). Open the battery door and insert a 9V battery properly
2). Pull the trigger to turn on the unit;
3). Aim at the target surface and pull the trigger, then temp-
erature will be shown on the LCD.
This unit is equipped with a laser, which is only used for
aiming.
2. Locating a Hot Spot
To find a hot spot, aim the thermometer outside of interest,
then scan across with an up and down motion until you
locate the hot spot. (Figure 1)
Figure 1
1.LCD display:
A: Measuring reading
B: Measuring unit
C: Laser on icon
D: Backlight on icon
E: Battery power icon
F: Scanning icon
G: Data hold icon
H: Mode/emissivity indicator
I: Data storge / read icon
J: Low temperature alarm icon
K: High temperature alarm icon
(1) Trigger: Full screen display will last for one seconds
after turning on. And turn to display reading with
SCAN icon. Release the trigger, display reading
with HOLD icon. Built in auto power off in 20sec.
(2) Laser / back light button: when back light turn on,
any operations will remain back light for 10 sec.
LCD indicate on/off status.
(3)(6) key functions: press 3 key, LCD subdisplay
blinks MAX-MIN-DIF-AVG-HAL-LAL-STO-EMS seg-
ment(only main display means normal measuring
mode) press 4 key to enter.
a. MAX: measuring maximum temperature
b. MIN: measuring minimum temperature
c. DIF: Basic on the reading before press 4 key,
compute the difference of current reading.
d. AVG: The average value of all measured in last 2
seconds
e. HAL: high temperature alarm--when selected HAL,
press 5 keys to set high temperature alarm trigger
and confirmed by pressing 4 key. When reading over
trigger, LCD display HI icon with BiBi audio sounds.
f. LAL: low temperature alarm--when selected LAL,
press 5 keys to set low temperature alarm trigger and
confirmed by pressing 4 key.
When reading over trigger, LCD display LOW icon
with BiBi audio sounds
g. STO: data storage--when selected STO, lock & DATA
& 1---indicator will shown when press 4 key. After
temperature read out press 6 key to store, then 2---
memory unit will be shown. There 80 groups memory
unit available. To recall the stored data in normal
measuring mode by pressing 6 key, remove all data
by pressing 6 keys for 3 seconds.
H. EMS: Emissivity setup-- press 5 key for emissivity
settings, press 4 key to save setup and back to
normal status.
1. Lens Cleaning:
Blow off loose particles using clean compressed air.
Gently brush remaining debris away with a moist cotton
swab. The swab may be moistened with water.
2. Case cleaning: Clean the case with a damp sponge/cloth
and mild soap.
Note:
1) Do not use solvent to clean plastic lens.
2) Do not submerge the unit in water.
MADE IN CHINA
1
SET
MODE
STO
CAL
7
3
4
6
2
5
5
Figure 2
VersionIR30-EN-00
Infrared thermometer
Instruction manual
GM11
5
0
I
N
F
RA
RE
D T
H
E
RM
O
M
E
T
ER
-
5
0 C ~ 11
5
0 C (
-
5
8 F ~ 2
1
0
2 F)
Accuracy
0~1650(32~3002) :±1.5(±2.7)
or±1.5%
-30~0(-22~32):±3 (±5)
Whichever is greater
Repeatability
1% of reading or 1
Response time
0.5~0.8 Sec, 95% response
8-14 um
Emissivity
0 ~40 (32 ~ 104)
-20 ~ 60 (-4~140)
Power
9V Alkaline or NiCd battery
Non-laser mode: 22 hrs;
Laser Models:12 hrs
50:1
Spectral response
Operating Humidity
Storage Temperature
Typical battery life
(Alkaline)
Distance to Spot size
Weight
Dimension
-30~1650 (-22~3002)
Temperature range
141*60*200mm
270g
Operating Temperature
10~95%RH non-condensing
up to 30(86)
Resolution
0.1 or 0.1
0.10~1.00 Adjustable (0.95 Preset)
(7) Clesius / Fahrenheit switch: Please open battery
and push the slide switch for convertsion.
MODEL:IR30
I
N
F
R
A
R
E
D T
H
E
R
M
OM
E
T
E
R
-
3
0 C ~ 1
6
5
0 C (
-
22 F ~ 30
0
2 F
)
-I
R30