Instructions

930XC-20C • 930XC-20M • 930XC-30F • 930XC-30P
35
Tempo Communications Inc. 1390 Aspen Way • Vista, CA 92081 USA • 800-642-2155
Events are presented by icons in link view, viewing each one of the events is the same as in trace view with the same hot
keys. The symbol indicates the selected event with event number. The overall fiber link information is shown in the black
line pictorial above the event link with relative position marks (white vertical lines) and distance information (total length and
location of selected event).
Figure 2
Events Summary
Beginning of fiber
Splice
Connector / Coupler
Macrobend
End of fiber
Events will be highlighted if the respective event is greater than the relevant setting in the Pass/Fail menu.
Pass/Fail Setup
Pass/Fail settings are accessed as shown in Figure 3.
Pass/Fail analysis is dependent on the settings as shown in Figure 4.
Figure 3 Figure 4
Ins. Loss
Measured events with insertion loss greater than this setting will be displayed red.
Reflectance
Measured events with reflectance greater than this setting will be displayed red.
Total Attn.
Measured links with a total attenuation greater than this setting will be displayed in red.
Total Loss
Measured links with a total loss greater than this setting will be displayed in red.
Total ORL (Optical Return Loss)
If the total ORL for the link is equal to or greater than this setting the link will be displayed red.
Thres. On/Off
Enable / Disable Pass/Fail function. On provides Pass/Fail analysis. Off disables the analysis.
Pass/Fail Settings