3640E Operator Manual

MAINTENANCE
3640E 330569 (8--01)
32
BATTERIES
The batteries are designed to hold their power for
long periods of time. The lifetime of the batteries is
limited to number of charges the batteries receive.
To get the most life from the batteries, recharge
them immediately when the battery discharge
indicator begins to blink.
Every 200 hours of operation, check for loose
battery connections and clean the surface of the
batteries, including terminals and cable clamps,
using a strong solution of baking soda and water.
Brush the solution sparingly over the battery tops.
Do not allow any baking soda solution to enter the
batteries. Use a wire brush to clean the terminal
posts and the cable connectors. Wipe off all
cleaning solution residue. After cleaning, apply a
coating of clear battery post protectant to the
terminals and the cable connectors. Keep the tops
of the batteries clean and dry.
Objects made of metal can potentially short circuit
the batteries. Keep all metallic objects off the
batteries. Replace any worn or damaged wires.
Check the electrolyte level in each battery cell
before and after charging, and after every 50
hours of operation. Do not charge the batteries
unless the fluid is slightly above the battery plates.
If needed, add just enough distilled water to cover
the plates. Never add acid to the batteries. Do not
overfill. Always keep the battery caps on, except
when adding water or taking hydrometer readings.
Home
Find...
Go To..