Convert a vacuum wand and panel filter configuration
IB 340171 (6--98) LITHO IN U.S.A. 1
No. 340171
Machine: 6080
Published: 6-98/00
System: SWEEPING
INSTRUCTION BULLETIN
NOTE: DO NOT DISCARD the Parts List from the Instruction Bulletin. Place the Parts
List in the appropriate place in your machine manual for future reference.
Retaining the Parts List will make it easier to reorder individual parts and will
save you the cost of ordering an entire kit.
NOTE: Numbers in parenthesis ( ) are reference numbers for parts listed in Bill of Materials.
Installation instructions for kit number 373148
SYNOPSIS / PROBLEM:
This kit contains the parts needed to convert a model 6080 sweeper configured with the high
airflow package to the reduced flow/live vacuum wand and panel filter configuration.
SPECIAL TOOLS / CONSIDERATIONS: None
(Estimated time to complete: 2 hours)
PREPARATION:
(Refer to FIG. 1 thru 4)
FOR SAFETY: Before leaving or servicing machine, stop on level surface and set parking
brake. Then turn off machine and remove key.
1. Open the engine/battery cover and engage the prop rod.
2. Remove the debris hopper.
3. Unlatch and remove the filter cover. Disconnect vacuum hose from filter cover.
(Refer to FIG.1)
INSTALLATION:
(Refer to FIG. 1 thru 4)
1. Remove and discard the existing vacuum tube, hose, and cuff from the machine.
(Refer to FIG. 1)
2. Remove and discard the the hose elbow coupling from the filter cover. (Refer to FIG. 1)
3. Remove and discard the washers and seal from the frame. (Refer to FIG. 1)
4. ELECTRIC MACHINE: Disconnect and remove the battery located over the existing
vacuum chamber.
WARNING: Always disconnect battery cables from machine before working
on electrical components.
5. Remove and discard the battery spacer. (Refer to FIG. 1)
6. LP MACHINE: Remove the LP tank from the machine. Unlatch the two LP front panel
locks and remove the panel from the machine.