Operator Manual

MAINTENANCE
101
T17 9020160 (32019)
CIRCUIT BREAKERS, FUSES, AND RELAYS
CIRCUIT BREAKERS
Circuit breakers are resettable electrical circuit
protection devices designed to stop the flow of
current in the event of a circuit overload. Once a
circuit breaker is tripped, reset it manually by
pressing the reset button after the breaker has
cooled down.
Circuit breakers 1 through 9 are located under the
operator seat behind the battery compartment
side cover.
Circuit breakers 10 through 15 are located behind
the steering shroud access panel.
Circuit breaker 16 is located inside the optional
light assembly mounted on top of the recovery
tank.
If the overload that caused the circuit breaker to
trip is still present, the circuit breaker will continue
to stop current flow until the problem is corrected.
The chart below shows the circuit breakers and
the electrical components they protect.
Circuit
Breaker
Rating Circuit Protected
CB1 60 A Water pickup module
CB2 50 A PreSweep module (Option)
CB3A 20 A Side brush sweep module
(Option)
CB3B 35 A Side brush scrub module
(Option)
CB4 2.5 A Key switch
CB5 2.5 A Water pick up module
CB6 2.5 A Scrub module
CB7A Not Used
CB7B 2.5 A PreSweep module (Option)
CB7C 2.5 A Side brush scrub module
(Option)
CB8 2.5 A ecH2O module
CB9 2.5 A ecH2O pump
CB10 15 A Spray nozzle (Option) / High
Pressure washer (Option)
CB11 15 A Lights (Option)
CB12 2.5 A Headlights (Option)
CB13 2.5 A Strobe light / Flashing light on
over head guard (Option)
CB14 2.5 A Strobe light / Flashing light on
recovery tank cover (Option)
CB15 15 A Power steering (Option)
CB16 2.5 A Backup alarm / light (Option)