Operator Manual

MAINTENANCE
127
T17 9020160 (52014)
ecH2O MODULE FLUSH PROCEDURE
This procedure is only required when the red
indicator light begins to flash and there is an
audible alarm.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off
machine, and set parking brake.
1. Open the right shroud to access the ecH2O
assembly.
2. Press the connector button to disconnect the
outlet hose from the ecH2O manifold.
NOTE: Look for arrows on the hose near where
the hose is coming from the bottom of the
ecH2O assembly to determine which hose is the
outlet hose.
3. Remove the drain hose from the ecH2O
compartment.
4. Connect the drain hose to the ecH2O outlet
hose.
5. Place the drain hose into a empty container.
6. Pour 2 gallons (7.6 liters) of white or rice
vinegar into the solution tank.