ec−H2O MODULE FLUSH PROCEDURE
This procedure is only required when the red
indicator light begins to flash and there is an
audible alarm.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off
machine, and set parking brake.
1. Open the right shroud to access the ec−H2O
assembly.
2. Press the connector button to disconnect the
outlet hose from the ec−H2O manifold.
NOTE: Look for arrows on the hose near where
the hose is coming from the bottom of the
ec−H2O assembly to determine which hose is the
outlet hose.
3. Remove the drain hose from the ec−H2O
compartment.
4. Connect the drain hose to the ec−H2O outlet
hose.
5. Place the drain hose into a empty container.
6. Pour 2 gallons (7.6 liters) of white or rice
vinegar into the solution tank.