Operator Manual

MAINTENANCE
128
T17 9020160 (52014)
7. Start the machine.
8. Press and release the ecH2O module flush
switch to start the flush cycle.
NOTE: The module will automatically shut off
when the flush cycle is complete (approximately 7
minutes). The module must run the full 7minute
cycle in order to reset the system indicator light
and alarm.
9. Pour 2 gallons (7.6 liters) of cool clean water
into the solution tank.
10. Press and release the flush switch to rinse
any remaining vinegar from the module. After
12 minutes, press the flush switch to turn off
the module.
11. Disconnect the drain hose from the ecH2O
manifold hose.
12. Reconnect the outlet hose to the ecH2O
manifold hose.
13. Return the drain hose to storage location in
the ecH2O compartment.
14. Close the right shroud.