Operator Manual
Table Of Contents
OPERATION
76
T17 9020160 (3−2019)
CLEAN THE LIVE WAND VACUUM FILTER
Clean the live wand vacuum filter every 50 hours
of operation.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off
machine, set parking brake, and remove key.
1. Unlatch and open the live wand vacuum
cover.
2. Remove the live wand vacuum filter and use
one of the following methods to clean the dust
filter.
TAPPING − Tap the filter, with the dirty side down,
gently on a flat surface. Do not damage the
edges of the filter. The filter will not seal properly
in the filter frame if the edges of the filter are
damaged.
AIR−Always wear eye protection when using
compressed air. Blow air through the dust filter
opposite the direction of the arrows. Never use
more than 690 kPa (100 psi) of air pressure and
never hold the nozzle closer than 50 mm (2 in) to
the filter. This may be done with the dust filter in
the machine.
3. Reinstall the filter, close the live wand vacuum
cover and latch it when finished.