T300e Operator Manual
OPERATION
Tennant T300e (02- 2017)
21
3. Rinse out solution tank with clean water
(Figure 56).
FIG. 56
4. Remove the solution tank filter and clean screen
after every 50 hours of use (Figure 57). Solution
filter is located under machine at rear. Drain
solution tank before removing filter .
FIG. 57
SERVICE INDICATOR CODES
When the machine or battery charger detects a fault, the service indicator will flash. A fault code will be provided to
determine problem as described below .
Flashing service
indicator
Flashing LED
fault code
T300e Control Panel
LED Fault C ode
= Flashing
CAUSE SOLUTION
Emergency stop button activated. Release emergency stop button and restart
machine.
SSS
Brush motor wiring, connector or control board
problem.
Contact service.
SS SS
Vacuum motor wiring, connector or control
board problem.
Contact service.
SS S
Propel circuit breaker tripped. Disconnect battery and reset circuit breaker . If
trip repeats, contact service.
S S
Software load failure. Contact service.
SSS
Propel I-Drive fault
Propel I-Drive communication lost
Restart machine. If fault repeats, contact
service.
SS S
Propel motor shorted fault Contact service.
SS
Brush motor over current Contact service.