T300e Operator Manual
MAINTENANCE
Tennant T300e (02- 2017)
31
FIG. 85
2. Unwrap the battery charger power cord from the
cord hooks.
3. Using a T25 star screwdriver, remove the two
screws located at the bottom of the control console
to access battery charger (Figure 86).
FIG. 86
4. Disconnect the battery cable, power cord and wire
harness from charger. Using a T25 star
screwdriver, remove the four screws that mount
charger to machine (Figure 87). Remove charger
from machine.
FIG. 87
5. Remove the black cap from bottom side of charger
to access the profile dial (Figure 88)
FIG. 88
6. Using a small standard screwdriver, turn the dial to
the appropriate battery type according to the
following chart (Figure 89).
FIG. 89
Dial
Position
Battery Description Settings
with AH Ranges
0 CAN- BUS setting*
1 Wet, Trojan 105- 155 AH
2 Wet, Enersys/Tab 105- 155 AH
3 AGM, Discover 80- 150 AH
4 AGM, Fullriver 80- 150 AH
5 AGM, TPPL, Enersys 20- 40 AH
6 Gel, Sonnenschein 80- 150 AH
* The CAN-BUS setting, dial position “0”, is the
software setting that is programmed to match battery
type supplied with machine. When the dial is manually
changed to a different setting, it should not be reset
back to “0” otherwise battery damage may result.
Service Application Software is required to reset dial
back to “0”. Contact Service.
7. Replace the black cap on charger, reinstall battery
charger and replace control console.
8. Reconnect the battery cable connection.
9. To set the BDI for the new battery type, plug the
on- board battery charger cord into an electrical
outlet. The machine’s software will automatically
reprogram the BDI to the new battery type.