User Manual

5.3.2. Presence Detection Mode
By default, Presence Detection is “Not activated”. Presence Detection can be activated
by ticking the checkbox “Activate Presence Detection”. Once activated:
The status notification switches between “Presence” and “Person moved away”
A meter counts the number of people passing by
The first slider sets the Presence detection range in cm.
The second slider sets a Presence detection threshold in seconds, after which a
person standing before the sensor is detected as present
5.3.3. Engagement Trigger Mode
The status of Engagement Trigger mode is either “Engagement” or
“Disengagement”
The first slider sets the engagement Trigger range in cm.
The second slider sets the Engagement time detection in seconds, after which a
person standing in front of the sensor is detected as engaged
The third slider sets the Disengagement time in seconds, after which a person
who has moved away from the sensor is detected as disengaged
5.3.4. Gesture Recognition Mode
5.3.4.1. Swipe Mode (Last gesture)
The “Last Gesture” status can be either “Right” or “Left”.
The first slider sets the minimum range in cm to detect swipe gestures
The second slider allows you to set the maximum threshold to detect gestures
5.3.4.2. Validation Mode
When a validation gesture is detected, the status displays “Validation”
The first slider sets a range in cm, under which a validation gesture is detected
The second slider sets a minimum time threshold in seconds, after which a hand
gesture is detected as a validation
5.3.4.3. Button to Reset Counters
Reset Bidirectional Counter: reset the counts to: 0 0 0
Reset Presence Counter: reset the count to: 0
Copyright © Terabee 2020
Terabee, 90 Rue Henri Fabre
01630, St Genis-Pouilly, France (next to CERN)
22/29