8.2.10.1 No-Motion
The No-Motion sensor is used to determine when an asset carrying an RSN is expected to be
in motion for a defined duration, but is not. The enabling of this sensor, its sensitivity, along
with the no-motion duration, is configurable under the No Motion tab. The Report
Frequency is a setting that defines the amount of time (in seconds) that must pass before
another event alarm is sent to the user application. It is recommended that this setting remain
at zero, which will issue an alarm for each event occurrence.
To configure this functionality, do the following:
1. Click the No Motion tab.
2. To enable No-Motion under this Behavior Profile, override and click the Enable No
Motion Event checkbox.
3. In the same manner, override the No Motion Sensitivity radio button selection.
4. Click to select the desired Sensitivity level radio button.
Note: it is recommended that the default sensitivity be selected until ample field
experience is obtained to justify a more or less sensitivity selection.