8.2.17.1 Troubleshooting the RSN
Using the same technique above, place the RSN you want to test in the RCT Cradle.
If you see the heartbeat LED is lit, then you know that the RSNs is working. If the RSN is
still not working (receiving or transmitting), then the trouble is with another component in
the IMS.
Using the illustration above, you can see the status of the LEDs on the RCT Cradle. Using
the RSN Troubleshooting Solutions table below, if an LED is not lit, look at the possible
causes in the Not Illuminated column. For a possible solution to why the LED is not
illuminated, look in the Description and Resolution columns.
Table 6: RSN Troubleshooting Solutions
LED Indicator Description Resolution
1. NETWORK
If illuminated, the
RSN has joined a
network.
2. TRANSMIT
If illuminated, the
RSN wake-up radio is
transmitting.
3. RECEIVE
If illuminated, the
RSN wake-up radio is
receiving.
4. HEARTBEAT
If flashing at a 1Hz
rate, the RSN radio is
enabled.
No LEDs illuminated RSN is not enabled. Enable the RSN.
No LEDs illuminated RSN is in deep sleep. Awaken the RSN.
No LEDs illuminated RSN is in shutdown. Reset the RSN (press the black power
switch in the RSN plug cavity).
No LEDs illuminated Battery is dead. Return to TeraHop Networks for battery
replacement.
4. Only
HEARTBEAT is
illuminated.
HEARTBEAT not
receiving. RSN not
hearing a Gateway
beacon.
Ensure the RSN is in range of
a Gateway, at least 300' without RF
interference.
Verify the paging channel is set properly
to 78. To verify, in the RCV, select the
Engineering level, and click Get RSN
data. Look in the middle section of the