User Manual

TeraHop Networks IMS Installation and Operation Manual V1.1 08-0000-01-R1
142
Parameter Description
Period
How frequently the RSN checks for the defined condition. It is recommended
the default value not be changed unless a specific application or field
experience determines a different frequency is required. The sample time is
in 100 ms increments.
Maintain
The number of consecutive samples the threshold must be exceeded to
generate an event. It is recommended that the default value not be changed
unless a specific application or field experience determines a different sample
rate is required.
Multiplying these two numbers ((P value x 100 ms) * M = event trigger)
calculates the timing for the triggering event. For example, a Period of 10
and a Maintain of 5 provides an event trigger time of 5000 ms or 5 seconds.
Alternatively, there is an advanced download window that is available to an Advanced User.
From the RCT menu, select Advanced RSN Download.
Note: You can also download user configurations from the RSN Direct Connect Downloader
screen.
8.2.23 Downloading RSN Factory Defaults
This feature is only available to RCT Advanced users.
Using the RSN Configuration Tool (RCT) and the RCT Cradle, if necessary, you can
download the factory defaults for an RSN.