User Manual

TeraHop Networks IMS Installation and Operation Manual V1.1 08-0000-01-R1
166
MMR System Will Not Power Up
Step
Yes
Go to
step
No
Go to
step
1. Disconnect the power connector that supplies a 12 VDC input to the MMR System
- -
2. Using a DVM, check the DC Voltage level on the connector. Is it 12 VDC ±1.5
VDC?
3 4
3. Replace the MMR System.
End End
4. Reconnect the connector disconnected in step 2 above.
- -
5. Refer to the wiring diagram, and determine the terminals on the distribution barrier
strip that supply 12 VDC to the MMR System.
- -
6. Using a DVM, check these terminals for 12 VDC. Is 12 VDC ±1.5 VDC present?
7 12
7. Disconnect the positive and negative wires that supply 12 VDC to the MMR
System from the distribution barrier strip.
- -
8. Disconnect the power connector at the base of the MMR System.
- -
9. Check the connector pins and associated wires for continuity. Is continuity present?
11 10
10. Repair or replace wiring as indicated.
End End
11. Power connector on the MMR System is defective. Replace the MMR System.
End End
12. Repair the terminal on the distribution barrier strip.
End End