Name Min Max Severity
Description
ACU Fault
Redundant
System
Critical Error
Indicates that the safety loop has been opened by the ACU.
Antenna rotation and transmission will cease.
Antenna Rotation Tellback Error
Redundant
System
Critical Error
Indicates that no antenna rotation tellback is received alt-
hough the antenna is expected to be rotating
BITE Measurement Log Disk
Limit Reached
Error
Indicates that the amount of disk space allocated to the
BITE Measurement Log has been used up
BITE Status Log Disk Limit
Reached
Error
Indicates that the amount of disk space allocated to the
BITE Status Log has been used up
BITE Warning and Error Log
Disk Limit Reached
Error
Indicates that the amount of disk space allocated to the
BITE Warning and Error Log has been used up
Blanking Map Status Error Indicates that the blanking map is missing
Board Temperature Er-
ror#External IO
85.0 500.0 Fatal Error
Indicates that the board surface temperature is outside the
recommended temperature range and that Mains has been
turned off to prevent component damage
Board Temperature Er-
ror#Motherboard
85.0 500.0 Fatal Error
Indicates that the board surface temperature is outside the
recommended temperature range and that Mains has been
turned off to prevent component damage
Board Temperature Error#PSU 85.0 500.0 Fatal Error
Indicates that the board surface temperature is outside the
recommended temperature range and that Mains has been
turned off to prevent component damage
Board Temperature Error#RxTx 85.0 500.0 Fatal Error
Indicates that the board surface temperature is outside the
recommended temperature range and that Mains has been
turned off to prevent component damage
Board Temperature Error#RxTx
Ctrl
85.0 500.0 Fatal Error
Indicates that the board surface temperature is outside the
recommended temperature range and that Mains has been
turned off to prevent component damage
Board Temperature Error#SSPA
Ctrl
85.0 500.0 Fatal Error
Board Temperature Error#SSPA
PA1
85.0 500.0 Fatal Error
Board Temperature Error#SSPA
PA2
85.0 500.0 Fatal Error
Board Temperature Error#SSPA
PA3
85.0 500.0 Fatal Error
Board Temperature Error#SSPA
PA4
85.0 500.0 Fatal Error