Users Manual

Name Min Max Severity
Description
Board Temperature Error#SSPA
PSU
85.0 500.0 Fatal Error
Indicates that the board surface temperature is outside the
recommended temperature range and that Mains has been
turned off to prevent component damage
Board Temperature Warn-
ing#External IO
75.0 85.0 Warning
Indicates that the board surface temperature is outside the
recommended temperature range
Board Temperature Warn-
ing#Motherboard
75.0 85.0 Warning
Indicates that the board surface temperature is outside the
recommended temperature range
Board Temperature Warn-
ing#PSU
75.0 85.0 Warning
Indicates that the board surface temperature is outside the
recommended temperature range
Board Temperature Warn-
ing#RxTx
75.0 85.0 Warning
Indicates that the board surface temperature is outside the
recommended temperature range
Board Temperature Warn-
ing#RxTx Ctrl
75.0 85.0 Warning
Indicates that the board surface temperature is outside the
recommended temperature range
Board Temperature Warn-
ing#SSPA Ctrl
75.0 85.0 Warning
Board Temperature Warn-
ing#SSPA PA1
75.0 85.0 Warning
Board Temperature Warn-
ing#SSPA PA2
75.0 85.0 Warning
Board Temperature Warn-
ing#SSPA PA3
75.0 85.0 Warning
Board Temperature Warn-
ing#SSPA PA4
75.0 85.0 Warning
Board Temperature Warn-
ing#SSPA PSU
75.0 85.0 Warning
Indicates that the board surface temperature is outside the
recommended temperature range
Chirp Reference Level Low
Error#f0
#
f0 – f7
Error
Indicates that the power of the transmitted signal as seen by
the receiver is lower than expected for frequency 0.
Communication Error#Board
Temperature Sensor#External IO
Error
Indicates that a communication error occurred and that no
valid reading could be obtained from the board surface
temperature sensor
Communication Error#Board
Temperature Sen-
sor#Motherboard
Error
Indicates that a communication error occurred and that no
valid reading could be obtained from the board surface
temperature sensor
Communication Error#Board
Temperature Sensor#PSU
Error
Indicates that a communication error occurred and that no
valid reading could be obtained from the board surface
temperature sensor
Communication Error#Board
Temperature Sensor#RxTx
Error
Indicates that a communication error occurred and that no
valid reading could be obtained from the board surface
3DJH
5HY&

6&$17(55DGDU6\VWHP
7HFKQLFDO0DLQWHQDQFH0DQXDO
+7