Users Manual
Name Min Max Severity
Description
Dynamic Measured STC file
Error
Error
Dynamic STC dB to DAC file
Error
Error
EEPROM VCO Multiplier Con-
figuration Missing
0 0 Error
Indicates that the VCO multiplier configuration is not
stored in the LRU EEPROM of the RxTx LRU. A 2x mul-
tiplier configuration is assumed, which will lead to garbled
radar video if used with a 4x multiplier unit. The correct
setting is available from the operation sheet of the RxTx
LRU and may be programmed in the LRU EEPROM from
the debug www page
EMCON Active 0 0 Warning
Indicates that the EMCON signal in connector X16 has
been activated by an external system
Encoder Power Supply Voltage
Level Error
0 0 Error
Indicates that the encoder power supply voltage level re-
quested could not be set
Failure Override Enabled Warn-
ing
Warning
Fan A Speed Error#Fan Control-
ler
0 500 Error
Indicates that the transceiver fan speed tellback is outside
the expected range
Fan A Speed Warning#Fan
Controller
500 1000 Warning
Indicates that the transceiver fan speed tellback is outside
the expected range
Fan Differential Pressure Er-
ror#Fan Controller
535.0 822.7 Error
Indicates that the latest valid reading of the transceiver fan
differential pressure sensor is outside the allowed range
Fan Differential Pressure Warn-
ing#Fan Controller
490.0 535.0 Warning
Indicates that the latest valid reading of the transceiver fan
differential pressure sensor is outside the recommended
range
FFT Bandwidth Exceeded Error Error
Indicates that the configured timing scenario exceeds the
signal processing capabilities of the transceiver and that
delays have been introduced to compensate for this (result-
ing in a lower duty cycle and PRF than could otherwise be
expected)
Firmware Initialization Error
Redundant
System
Critical Error
Set when the application was unable to establish access to a
firmware board.
Firmware Module Not Present
Error
Redundant
System
Critical Error
Set when the application was unable to establish access to a
firmware module.
Forward Power Calibration
Table Invalid Error#RxTx Ctrl
Error
Indicates an error occurred while reading RxTx Controller
calibration data from the PC hard disk
Forward Power Calibration
Table Invalid Error#SSPA
Error
Indicates an error occurred while reading SSPA calibration
data from the PC hard disk
3DJH
5HY&
6&$17(55DGDU6\VWHP
7HFKQLFDO0DLQWHQDQFH0DQXDO
+7