+7
%,7(HUURUVDQGZDUQLQJV
7KHIROORZLQJOLVWV%,7(HUURUVDQGZDUQLQJVWKDWPD\EHGHWHFWHGLQWKHV\VWHP
3OHDVHQRWHWKDWWKHOLVWLVQRWH[KDXVWLYH)RUDFRPSOHWHOLVWRIHUURUVDQGZDUQ
LQJVSOHDVHUHIHUWRGRF',³6&$17(56HULHV7UDQVFHLYHU&RQWURO
3URWRFRO'DWD'HILQLWLRQ6HUYLFH$FFHVV0RGH´
Name Min Max Severity Description
ACP Polarity#EXTIO Error
ACP Polarity#RXTX Error
ACU Fault
Redundant
System
Critical
Error
Indicates that the safety loop has been opened
by the ACU. Antenna rotation and transmission
will cease.
Antenna Pattern File Error Error
The transceiver was unable to read the antenna
pattern file or file format was not correct
Antenna Rotation Tellback Error
Redundant
System
Critical
Error
Indicates that no antenna rotation tellback is
received although the antenna is expected to be
rotating
Antenna Speed Not Calibrated 0 0 Error Indicates that antenna speed is not calibrated
ARP Polarity#EXTIO Error
ARP Polarity#RXTX Error
Asterix Database Overload Error 4095 4096 Error
The Asterix database is full. New messages will
be discarded
Asterix Database Overload Warning 3996 4096 Warning
The Asterix database is approaching its max
capacity of 4096 messages.
Azimuth Out Of Range#EXTIO Error
Azimuth Out Of Range#RXTX Error
BITE Measurement Log Disk Limit
Reached
Error
Indicates that the amount of disk space allocat-
ed to the BITE Measurement Log has been used
up
BITE Status Log Disk Limit Reached Error Indicates that the amount of disk space allocat-