Users Manual
3DJH
5HY&
6&$17(55DGDU6\VWHPV
7HFKQLFDO0DLQWHQDQFH0DQXDO
+7
Name Min Max Severity Description
Fan A Speed Error#Fan Controller 0 500 Error
Indicates that the transceiver fan speed tellback
is outside the expected range
Fan A Speed Warning#Fan Controller 500 1000 Warning
Indicates that the transceiver fan speed tellback
is outside the expected range
Fan Differential Pressure Error#Fan Con-
troller
535.0 822.7 Error
Indicates that the latest valid reading of the
transceiver fan differential pressure sensor is
outside the allowed range
Fan Differential Pressure Warning#Fan
Controller
490.0 535.0 Warning
Indicates that the latest valid reading of the
transceiver fan differential pressure sensor is
outside the recommended range
FFT Bandwidth Exceeded Error Error
Indicates that the configured timing scenario
exceeds the signal processing capabilities of the
transceiver and that delays have been intro-
duced to compensate for this (resulting in a
lower duty cycle and PRF than could otherwise
be expected)
Firmware Initialization Error#MainsOn
Redundant
System
Critical
Error
Set when the application was unable to estab-
lish access to a firmware board.
Firmware Initialization Er-
ror#NodeManagerCentral
Redundant
System
Critical
Error
Set when the application was unable to estab-
lish access to a firmware board.
Firmware Module Not Present Er-
ror#MainsOn
Redundant
System
Critical
Error
Set when the application was unable to estab-
lish access to a firmware module.
Firmware Module Not Present Er-
ror#NodeManagerCentral
Redundant
System
Critical
Error
Set when the application was unable to estab-
lish access to a firmware module.
Forward Power Calibration Table Invalid
Error#RxTx Ctrl
Error
Indicates an error occurred while reading RxTx
Controller calibration data from the PC hard
disk
Forward Power Calibration Table Invalid
Error#SSPA
Error
Indicates an error occurred while reading SSPA
calibration data from the PC hard disk
Forward Power Calibration Table Used Not
Verified Warning#RxTx Ctrl
Warning
Indicates a testing RxTx Controller table is
used
Forward Power Calibration Table Used Not
Verified Warning#SSPA
Warning
Indicates a testing SSPA calibration table is
used
Forward Power Low Warning
Indicates when currently transmitted power is
lower than warning level but higher than speci-