Users Manual
3DJH
5HY&
6&$17(55DGDU6\VWHPV
7HFKQLFDO0DLQWHQDQFH0DQXDO
+7
Name Min Max Severity Description
is above the expected range
Over Voltage Error#PSU 13V5 14.2 100.00 Error
Indicates that the supply voltage measurement
is above the expected range
Over Voltage Error#PSU 24V0 25.2 100.00 Error
Indicates that the supply voltage measurement
is above the expected range
Over Voltage Error#PSU 12V0 1 12.6 100.00 Error
Indicates that the supply voltage measurement
is above the expected range
Over Voltage Error#PSU 12V0 2 12.6 100.00 Error
Indicates that the supply voltage measurement
is above the expected range
Over Voltage Error#PSU 13V5 I 14.2 100.00 Error
Indicates that the supply voltage measurement
is above the expected range
Over Voltage Error#PSU 12V0 VP 12.6 100.00 Error
Indicates that the supply voltage measurement
is above the expected range
Over Voltage Error#SSPA Analog 5V0 5.5 100.0 Fatal Error
Over Voltage Error#SSPA Digital 5V0 5.5 100.0 Fatal Error
Over Voltage Error#SSPA PSU N8V5 -8.1 100.0 Fatal Error
Over Voltage Error#SSPA PSU P8V2 8.6 100.0 Fatal Error
Over Voltage Error#SSPA PSU P6V0 6.3 100.0 Fatal Error
Over Voltage Error#SSPA PSU VCC3V3 3.5 100.0 Fatal Error
Over Voltage Error#SSPA PSU VCC5V0 5.3 100.0 Fatal Error
Over Voltage Error#SSPA 3V3 3.8 500.0 Fatal Error
Parameter Change Log Disk Limit Reached Error
Indicates that the amount of disk space allocat-
ed to the Parameter Change Log has been used
up
PEX Overload#Surface Error
The number of received plots from HDL PEX
is to big.
Phase Shifter Calibration Table Invalid
Error#SSPA
Error
Phase Shifter Calibration Table Used Not
Verified Warning#SSPA
Warning
Pilot Tone Attenuation file Error Error
Plot Publisher Input Link#ClutterMap Error Could not connect to surface data input source.
Plot Publisher Input Link#Surface Error Could not connect to surface data input source.