Users Manual

3DJH
5HY&

6&$17(55DGDU6\VWHPV
7HFKQLFDO0DLQWHQDQFH0DQXDO
+7
Name Min Max Severity Description
Under Voltage Error#PSU 24V0 -100.0 22.8 Error
Indicates that the supply voltage measurement
is below the expected range
Under Voltage Error#PSU 12V0 1 -100.0 11.4 Error
Indicates that the supply voltage measurement
is below the expected range
Under Voltage Error#PSU 12V0 2 -100.0 11.4 Error
Indicates that the supply voltage measurement
is below the expected range
Under Voltage Error#PSU 13V5 I -100.0 12.8 Error
Indicates that the supply voltage measurement
is below the expected range
Under Voltage Error#PSU 12V0 VP -100.0 11.4 Error
Indicates that the supply voltage measurement
is below the expected range
Under Voltage Error#SSPA Analog 5V0 -100.0 4.5 Fatal Error
Under Voltage Error#SSPA Digital 5V0 -100.0 4.5 Fatal Error
Under Voltage Error#SSPA PSU N8V5 -100.0 -8.9 Fatal Error
Under Voltage Error#SSPA PSU P8V2 -100.0 7.8 Fatal Error
Under Voltage Error#SSPA PSU P6V0 -100.0 5.7 Fatal Error
Under Voltage Error#SSPA PSU VCC3V3 -100.0 3.1 Fatal Error
Under Voltage Error#SSPA PSU VCC5V0 -100.0 4.7 Fatal Error
Under Voltage Error#SSPA 3V3 -100.0 2.8 Fatal Error
Video Server Link Error#Surface 0 1 Error
Indicates that the communication between the
main software node and the video server is not
established
Waveguide Not Available Error
Critical
Error
Indicates that the waveguide switch tellback
reports that a waveguide switch is connected
and in the position where this transceiver does
not have access to the waveguide, even though
the Redundant System Mode parameter is set to
Single
Waveguide Switch 2 error Error Indicates that waveguide switch is out of sync
Waveguide Switch Tellback Error Error
Indicates that the waveguide switch tellback
was unexpected, i.e. the tellback was invalid or
the waveguide switch position did not match
the requested position