Certifications 2

SDS No.: 633048 V004.0
TEROSON MS 939 WH
Page 6 of 14
Derived No-Effect Level (DNEL):
Name on list
Application
Area
Route of
Exposure
Health Effect
Exposure
Time
Value
Remarks
Trimethoxyvinylsilane
2768-02-7
Workers
dermal
Long term
exposure -
systemic effects
3,9 mg/kg
Trimethoxyvinylsilane
2768-02-7
Workers
inhalation
Long term
exposure -
systemic effects
27,6 mg/m3
Trimethoxyvinylsilane
2768-02-7
General
population
dermal
Long term
exposure -
systemic effects
7,8 mg/kg
Trimethoxyvinylsilane
2768-02-7
General
population
inhalation
Long term
exposure -
systemic effects
6,7 mg/m3
Trimethoxyvinylsilane
2768-02-7
General
population
oral
Long term
exposure -
systemic effects
0,3 mg/kg
Bis(2,2,6,6-tetramethyl-4-piperidyl) sebacate
52829-07-9
Workers
dermal
Long term
exposure -
systemic effects
0,5 mg/kg
Bis(2,2,6,6-tetramethyl-4-piperidyl) sebacate
52829-07-9
Workers
Inhalation
Long term
exposure -
systemic effects
0,68 mg/m3
Bis(2,2,6,6-tetramethyl-4-piperidyl) sebacate
52829-07-9
General
population
Inhalation
Long term
exposure -
systemic effects
0,17 mg/m3
Bis(2,2,6,6-tetramethyl-4-piperidyl) sebacate
52829-07-9
General
population
dermal
Long term
exposure -
systemic effects
0,25 mg/kg
Bis(2,2,6,6-tetramethyl-4-piperidyl) sebacate
52829-07-9
General
population
oral
Long term
exposure -
systemic effects
0,05 mg/kg
Biological Exposure Indices:
8.2. Exposure controls:
Engineering controls:
Ensure good ventilation/extraction.
Respiratory protection:
The product should only be used at workplaces with intensive ventilation/extraction.
If intensive ventilation/extraction is not possible respiratory protection equipment with ABEK P2 filter (EN 14387) should be
worn.
Hand protection:
Chemical-resistant protective gloves (EN 374).
Suitable materials for short-term contact or splashes (recommended: at least protection index 2, corresponding to > 30 minutes
permeation time as per EN 374):
nitrile rubber (NBR; >= 0.4 mm thickness)
Suitable materials for longer, direct contact (recommended: protection index 6, corresponding to > 480 minutes permeation time
as per EN 374):
nitrile rubber (NBR; >= 0.4 mm thickness)
This information is based on literature references and on information provided by glove manufacturers, or is derived by analogy
with similar substances. Please note that in practice the working life of chemical-resistant protective gloves may be considerably
shorter than the permeation time determined in accordance with EN 374 as a result of the many influencing factors (e.g.
temperature). If signs of wear and tear are noticed then the gloves should be replaced.
Eye protection:
Goggles which can be tightly sealed.
Protective eye equipment should conform to EN166.