Certifications 2

SDS No.: 76601 V014.1
TEROSON SB 2444 340G EGFD
Page 11 of 21
Respiratory protection:
In case of aerosol formation, we recommend wearing of appropriate respiratory protection equipment with ABEK P2 filter (EN
14387).
This recommendation should be matched to local conditions.
Hand protection:
Chemical-resistant protective gloves (EN 374). Suitable materials for short-term contact or splashes (recommended: at least
protection index 2, corresponding to > 30 minutes permeation time as per EN 374): Isobutylene-isoprene rubber (IIR; >= 0.7 mm
thickness) Suitable materials for longer, direct contact (recommended: protection index 6, corresponding to > 480 minutes
permeation time as per EN 374): Isobutylene-isoprene rubber (IIR; >= 0.7 mm thickness) This information is based on literature
references and on information provided by glove manufacturers, or is derived by analogy with similar substances. Please note
that in practice the working life of chemical-resistant protective gloves may be considerably shorter than the permeation time
determined in accordance with EN 374 as a result of the many influencing factors (e.g. temperature). If signs of wear and tear are
noticed then the gloves should be replaced.
Eye protection:
Goggles which can be tightly sealed.
Protective eye equipment should conform to EN166.
Skin protection:
Protective clothing that covers arms and legs.
Wear protective equipment.
Protective clothing should conform to EN 14605 for liquid splashes or to EN 13982 for dusts.
Advices to personal protection equipment:
Use only personal protection that's CE-labelled according to Directive 89/686/EEC (Europe) or to Regulation No. 819 of 19
August 1994 (Norway).
The information provided on personal protective equipment is for guidance purposes only. A full risk assessment should be
conducted prior to using this product to determine the appropriate personal protective equipment to suit local conditions.
Personal protective equipment should conform to the relevant EN standard.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
Appearance
liquid
liquid
beige
Odor
of solvent
Odour threshold
No data available / Not applicable
pH
No data available / Not applicable
Melting point
No data available / Not applicable
Solidification temperature
No data available / Not applicable
Initial boiling point
(1.013 hPa)
63,0 °C (145.4 °F)
Flash point
-24 °C (-11.2 °F); DIN 51755 Closed cup flash point
Evaporation rate
No data available / Not applicable
Flammability
No data available / Not applicable
Explosive limits
lower
upper
1,10 %(V)
11,5 %(V)
Vapour pressure
(20,0 °C (68 °F))
< 250 hPa
Vapour pressure
(55 °C (131 °F))
450 mbar
Relative vapour density:
No data available / Not applicable
Density
(20 °C (68 °F))
0,87 g/cm3
Bulk density
No data available / Not applicable
Solubility
No data available / Not applicable
Solubility (qualitative)
(Solvent: Water)
Partially soluble
Partition coefficient: n-octanol/water
No data available / Not applicable
Auto-ignition temperature