Datasheet

TESLA BLATNÁ, a.s., Palackého 644, 388 15 Blatná, Czech Republic
Phone: +420 383 415 366, E-mail: tesla@tesla-blatna.cz
BLATNÁ, a.s.
aaaaaa.s.
Electrochemical Sensor Platform BE3
Electrochemical sensor platform BE3 is designed for gas detection. This is a three-electrode
structure with a working (WE), reference (RE) and counter electrodes (CE). Patterns of
reference, counter and working electrodes are created by sputtering of platinum on a ceramic
substrate. The sensitive layer on the platform can be applied by various thick- or thin-film
technologies.
Applications: Typical areas of application for
this platform are different types of
gas sensors (NOx, etc.) for
measuring air quality and
environmental protection.
Connection: Ag welded wire ø 0.25 mm,
DIL connectors or
(customer specifications)
Temperature range: -30 °C to +200 °C (for the platform)
Dimensions: 7.25 x 8.75 x 0.6 mm
Example of the application: Detection NO
2
gas
functional layer: solid polymer electrolyte
sensitivity: 600 nA/ppm
detection range: 0-10 ppm
time response: 60/100 s
1a electrode pad (WE)
1b working electrode (WE)
2a electrode pad (RE)
2b reference electrode (RE)
3a electrode pad (CE)
3b counter electrodes (CE)
4 substrate
5 solid polymer electrolyte
WE RE CE

Summary of content (1 pages)