User Manual
Table Of Contents
- IMPORTANT SAFETY INFORMATION
- PRODUCT OVERVIEW
- INSTALLATION
- In the Box
- Tools
- Installation Considerations
- Step 1: Prepare Wirebox for Conduit Fittings and Bushings
- Step 2: Prepare Mounting Surface
- Step 3: Prepare Wirebox and Mount to Wall
- Step 4: Route Wiring Through Wirebox
- Step 5: Strip and Land Wiring
- Step 6: Attach Wall Connector to Wirebox
- Step 7: Energize Wall Connector
- COMMISSIONING PROCEDURE
- POWER SHARING
- WALL CONNECTOR LEDS
- WARRANTY INFORMATION
- _
PRODUCT OVERVIEW
This manual applies to Wall Connectors identified by part number 1457768-**-*.
Product Specifications
Voltage and Wiring Nominal 200-240 V AC single-phase
Current Output Range 12 – 48 amps
Terminal Blocks
12-4 AWG (3.5 - 25 mm
2
), copper only
Supported Conduit Sizing ¾ in (21 mm) default, 1 in (27 mm) optional
Grounding Scheme TN/TT
Frequency 50/60 Hz
Cable Length 7.3 m (24 ft)
Wall Connector Dimensions
Height: 13.6 in (345 mm)
Width: 6.1 in (155 mm)
Depth: 4.3 in (110 mm)
Wire Box Bracket Dimensions
Height: 9.8 in (250 mm)
Width: 4.7 in (120 mm)
Depth: 2.0 in (50 mm)
Weight (including wirebox) 10 lb. (4.5 kg)
Operating Temperature -22˚F to 122˚F (-30˚C to 50˚C)
Storage Temperature -40˚F to 185˚F (-40˚C to 85˚C)
Enclosure Rating Type 3R
Ventilation Not required
Means of Disconnect External branch circuit breaker
Ground Fault Circuit Interrupter Integrated, no additional required (CCID20)
Wi-Fi 2.4 GHz, 802.11b/g/n
Agency Approvals cULus - E351001
Transportation and storage: Ensure that Wall Connector is within storage temperature when moving,
transporting, or storing.
This device complies with part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
5Gen 3 Wall Connector Manual