Instruction Manual

8
d. ACA
Range Resolution Accuracy Overload Protection
200µA 0.1µA ±1% of reading, Fuse*
2mA 0.001mA ±3 digits
F600V, 2A, 31CM
20mA 0.01mA
200mA 0.1mA ±1.8% of reading,
2A 0.001A ±3 digits
10A 0.01A ± 3% of reading, ± 7 digits Fuse* F600V, 10A, 31CM
e. OHM (Resistance, )
Range Resolution Accuracy Overload Protection
200 0.1 ±0. 5% of reading, 600V DC or
2k 0.001k ±1 digit AC Peak
20k 0.01k
200k 0.1k
2M 0.001M
20M 0.01M ±1% of reading, ±2 digits
f. Diode Test
Test Voltage Max Test Current Over Load Protection
2.5V Approx. 1mA 600 V DC or Peak AC
g. Continuity Buzzer
Test Voltage Threshold Over Load Protection
2.5V <100 600 V DC or Peak AC
h. General Specifications
Power Supply 9 Volt Battery
Battery Life 560 hrs. Alkaline
Size (H x L x W) 33mm x 86mm x 187mm
(1.3” x 3.4” x 7.4”)
Weight 340g (12 oz)
3. Specifications
IEC 1010 Over Voltage:
CAT II - 1000V
CAT III - 600V
Pollution Degree 2
a. DCV
Range Resolution Accuracy Impedance
200mV 0.1mV ±0.5% of reading, 10M
2V 0.001V ±2 digits
20V 0.01V
200V 0.1V
1000V 1V
b. ACV (45Hz to 450Hz)
Range Resolution Accuracy Impedance
200mV 0.1mV ±1.2% of reading, 10M
±3 digits
2V 0.001V ±0.8% of reading,
20V 0.01V ±3 digits
200V 0.1V
750V 1V
c. DCA
Range Resolution Accuracy Overload
Protection
200µA 0.1µA ±0.5% of reading, Fuse*
2mA 0.001mA ±1 digit F600V, 2A, 31CM
20mA 0.01mA
200mA 0.1mA ±1.2% of reading,
2A 0.001A ±1 digit
10A 0.01A ±2% of reading, Fuse*
±5 digits F600V, 10A, 31CM
9
*Warning: Use only correct size, voltage and current rated fuses.
Test Leads: Use only correct type and overvoltage category rating.
*Warning: Use only correct size, voltage and current rated fuses.
Test Leads: Use only correct type and overvoltage category rating.
UL 3111-1