User manual

TT-HVP 2739 High-Frequency High Voltage Probe
E-6
4. COMPENSATION ADJUSTMENT
The following adjustment is required whenever the probe is
transferred from one oscilloscope or input channel to another.
Connect the probe to the oscilloscope, apply a 200Hz square
wave to the probe tip and adjust the oscilloscope controls to
display a few cycles of the waveform. Adjust the trimmer located
in the BNC plug for a flat topped square wave.
Illustration of 200Hz square wave adjustment.
Adjust the frequency
response of the probe
to match your
oscilloscope by the
adjust bar attached
only.