9.1 Overview of TT CC series current probes
MODELL
TT-CC 220
TT-CC 550 TT-CC 770 TT-CC 990
Empfindlichkeit
(umschaltbar)
100
mV/A
10
mV/A
200
mV/A
20
mV/A
500
mV/A
50
mV/A
1 V/A
100
mV/A
max. Current DC 10 A 100 A 5 A 50 A 7 A 70 A 4 A 40 A
max. Current DC+ACp 10 A 100 A 5 A 50 A 7 A 70 A 4 A 40 A
max. Current ACp 10 A 100 A 5 A 50 A 7 A 70 A 4 A 40 A
max. Current ACp-p 20 A 200 A 10 A 100 A 14 A 140 A 8 A 80 A
max. RMS CAT III 7,07 A 70,7 A 3,54 A 35,4 A 5 A 50 A 2,8 A 28 A
max. RMS CAT II 7,07 A 70,7 A 3,54 A 35,4 A 5 A 50 A 2,8 A 28 A
max. RMS CAT I 7,07 A 70,7 A 3,54 A 35,4 A 5 A 50 A 2,8 A 28 A
max. Working Voltage 600 VAC RMS CAT II / 300 VAC RMS CAT III
Pollution Degree 2
DC Measurement
Accuracy (typical))
±3% ±50
mA
@ 100
mV/A
(50 mA to
10
A
peak)
±4% ±50
mA
@ 10
mV/A
(500 mA
to
40
A peak)
±15% max
@
10 mV/A
(40
A peak
to
100
A peak)
<±3% ±30
mA
@ 200
mV/A
(30 mA to 5
A
peak)
±4% ±300
mA
@ 20
mV/A
(300 mA
to
20
A
peak)
±15% @
200
mV/A
(20
A peak
to
50
A peak)
<±3% ±20
mA
@ 500
mV/A
(20 mA to
14
A
peak)
±4% ±200
mA
@ 50
mV/A
(200 mA
to
100
A
peak)
±15% @
50
mV/A
(100
A peak
to
140
A peak)
<±3% ±10
mA
@ 1 V/A
(10
mA to 8
A
peak)
±4% ±100
mA
@ 100
mV/A
(100 mA
to
80
A peak)
Bandwidth (
-
3dB)
DC
–
300
kHz
DC
–
500
kHz
DC
–
1
MHz
DC
–
1,5
MHz
Phase Shift
See Figure 9
Anstiegs
-
und
Abfallzeit
1,2
µs
(typ.)
0,7
µs
(typ.)
0,35
µs
(typ.)
0,23
µs
(typ.)
Battery Type
9
V
Alkaline
(NEDA
1604A,
IEC
6LR61)
Typ. Battery Life
8
h
6
h
4
h
Operating Temperature
0
to
50
°C
Storage Temperature
-
20
to
80
°C
Max. Operating
Humidity
95
% humidity, 0 to 40°C
45
% humidity, 40 to 50°C
Di
mensions
280
mm
x
70
mm
x
32
mm
262
mm
x
81
mm
x
36
mm
Maximum Conductor
11
mm
10,3
mm
Cable Length
100 cm
100 cm
100 cm
100 cm
Weight(without battery)
260 g
260 g
310 g
310 g