ACTIVE DIFFERENTIAL PROBES SERIES 8000
TT-SI 8071 TT-SI 8110
Bandwidth (-3dB
70MHz
TT-SI 8050 70MHz
100MHz
TT-SI 8010A 70MHz
TT-SI 8051 100MHz
TT-SI 8010B 100MHz
TT-SI 8052 200MHz
Rise Time ≤5ns
TT-SI 8050 ≤5ns
≤3.5ns
TT-SI 8010A ≤5ns
TT-SI-8051 ≤3,5ns
TT-SI 8010B ≤3,5ns
TT-SI 8052 ≤1,75ns
DC-Accuracy ±2% ±2% ±2% ±2%
Attenuation Ratio x10/x100 x50/x500 x100/x1000 x100/x1000
Maximum Input Voltage
Differential Mode
(DC+Peak AC)
x10 ±70V x50 ±150V x100 ±280V x100 ±700V
x100 ±700V x500 ±1500V x1000 ±2800V x1000 ±7000V
Maximum Input Voltage
Common Mode
(DC+Peak AC)
±700V ±1500V ±2800V ±7000V
Maximum Input Voltage
each Side to Ground (Vrms)
450V CAT II
600V
600V CAT III
1000V CAT II
600V CAT III
1000V CAT II
1000V CAT III
2300V
Input
Impedance
Single-
Ended to
Ground
2.5MΩ 5MΩ 5MΩ 20MΩ
Between
Inputs
5MΩ 10MΩ 10MΩ 40MΩ
Input
Capacitance
Single-
Ended to
Ground
4pF 4pF 4pF 5pF
Between
Inputs
2pF 2pF 2pF 2.5pF
CMRR
DC
80dB 80dB 80dB 80dB
100kHz
60dB 60dB 60dB 60dB
1MHz
50dB 50dB 50dB 50dB
Input referred Noise
70V
20mV
150V
50mV
280V
100mV
700V
200mV
700V
120mV
1500V
300mV
2800V
600mV
7000V
1.2V
Differential Overvoltage
Detection Level
x10 ≥70V x50 ≥150V x100 ≥280V x100 ≥700V
x100 ≥700V x500 ≥1500V x1000 ≥2800V x1000 ≥7000V
Propagation
Delay
Probe approx. 9ns
BNC Cable approx. 5ns
Bandwidth Limit Filters ≥-3dB@5MHz
Weight 230g
Input Lead Length 28cm (17cm for TT—SI 8052)
Automatic Save Yes
Offset Setting Function
Yes when set in test mode
Termination Load ≥100kΩ
Power Supply USB 5V/1A and 220V Adapter
Safety standard EN61010-031: 2015