ACTIVE DIFFERENTIAL PROBES INSTRUCTION MANUAL TT-SI 8000 SERIES
Safety Summary To avoid personal injury and/or product damage, review and comply with the following safety precautions. These precautions apply to both operating and maintenance personnel and must be followed during all phases of operation, service, and repair of this probe. A WARNING statement calls attention to an operating procedure, practice, or condition, which, if not followed correctly, could result in injury or death to personnel.
Not for Critical Applications This probe is not authorized for use in contact with the human body or for use as a component in a life-support device or system. Do Not Substitute Parts Do not install substitute parts or perform any unauthorized modification to the instrument. Only Qualified Personnel Only qualified personnel should use this probe.
Definitions Measurement Category II (CAT II) refers to local-level electrical distribution, such as that provided by a standard wall outlet or plug-connected equipment. Examples of CAT II measurements would be household appliances, portable tools, and similar modules. Measurement Category III (CAT III) refers to measurements on hard-wired equipment in fixed installations, distribution boards, and circuit breakers that form part of a building wiring installation.
1 Introduction Overview The TT-SI 8000 differential probe series allows safe, accurate measurement between two voltage points where neither point is referenced to ground. The probes are designed for high sensitivity measurements up to 200 MHz bandwidth and up to 7000V differential voltage. The probes are compatible with oscilloscopes from all major manufacturers.
Model Overview TT-SI 8071 Max. Input Differential Voltage 700V TT-SI 8050 1500V 70MHz x50/x500 TT-SI 8051 1500V 100MHz x50/x500 TT-SI 8052 1500V 200MHz x50/x500 TT-SI 8110 2800V 100MHz x100/x1000 TT-SI 8010A 7000V 70MHz x100/x1000 TT-SI 8010B 7000V 100MHz x100/x1000 Model Bandwidth Attenuation 70MHz x10/x100 2 Using the Probe WARNING At the time of powering on the probe, the input leads must not be connected to an item to be tested. Never operate the probe with the case open.
3 Product Overview Probe Inputs Maximum Differential Voltage Common Mode Voltage and Maximum Input Voltage to Earth Overrange Indicator Attenuation Selection Button and Indicators Bandwidth Limit Button and Indicators Audible Overrange On/Off Button and Indicators Load Requirement USB Power Lead Input BNC Output Man_8000_0120 www.testec.
4 Specifications TT-SI 8071 Bandwidth (-3dB) 70MHz Rise Time ≤5ns DC-Accuracy Attenuation Ratio Maximum Input Voltage Differential Mode (DC+Peak AC) TT-SI 8051 100MHz TT-SI 8052 200MHz TT-SI 8050 ≤5ns TT-SI-8051 ≤3,5ns TT-SI 8052 ≤1,75ns TT-SI 8010A 70MHz TT-SI 8010B 100MHz TT-SI 8010A ≤5ns TT-SI 8010B ≤3,5ns 100MHz ≤3.
5 Voltage Derating Curve Derating Curve TT-SI 8071 TTSI 7005 Voltage Derating Derating Curve TT-SI 8050, 8051, 8052 Man_8000_0120 www.testec.
Derating Curve TT-SI 8110 Derating Curve TT-SI 8010A, 8010B Man_8000_0120 www.testec.
6 Accessories Description TT-SI CR81 - Alligator Clips one pair black and red 1000V CAT III / 600V CAT IV TT-SI CR82 - Alligator Clips one pair black and red 1000V CAT III / 600V CAT IV TT-SI GR82 - Pincer Clips one pair black and red 1000V CAT III TT-SI GR81 - Hook Clips one pair black and red 1000V CAT III TT-SI TL8 - Extension Test Leads Leads 4mm, one pair black and red 1000V CAT III, 100cm TT-SI BN8 - BNC Output Lead, 100cm TT-SI USB8 - USB Power Lead, 150cm TT-SI NT8 – USB Mains Adapter 5V/1A
7 Cleaning This probe does not require any particular cleaning. If necessary, clean the case with a soft cloth. WARNING Dry the probe thoroughly before attempting to make voltage measurements. CAUTION Avoid immersing or using abrasive cleaners or solvents containing Benzene (or similar solvents) on the probe as these can cause deterioration of the probe body and cables. Man_8000_0120 www.testec.
8 Service & Warranty Information Limited One-Year Warranty Testec Elektronik GmbH warrants these products to be free from defective material or workmanship for a period of 1 year from the date of original purchase. Under this warranty, Testec Elektronik GmbH is limited to repairing the defective device when returned to the factory, shipping charges prepaid, within the warranty period.
Man_700_0919 www.testec.
TT-SI 8XXX Differential Probe User’s Manual © 2020 TESTEC Elektronik GmbH. All rights reserved. Unauthorized duplication of TESTEC documentation materials is strictly prohibited. Customers are permitted to duplicate and distribute TESTEC documentations for internal educational purposes Man_700_0919 www.testec.