testo · Smart Probes Instruction manual
1 Contents 1 Contents 1 Contents ...................................................................................................3 2 Safety and the environment ....................................................................5 2.1. About this document ........................................................................5 2.2. Ensure safety...................................................................................6 2.2.1. 2.2.2. 2.2.3. 2.3. Safety and the testo 510i .................
1 Contents 7 Maintaining the product ....................................................................... 15 7.1. Maintaining Smart Probes ............................................................. 15 7.2. Smart Probes App......................................................................... 15 8 Tips and assistance .............................................................................. 16 8.1. Questions and answers ................................................................ 16 8.2.
2 Safety and the environment 2 Safety and the environment 2.1. About this document Use > Please read this documentation through carefully and familiarize yourself with the product before putting it to use. Pay particular attention to the safety instructions and warning advice in order to prevent injuries and damage to the products. > Keep this document to hand so that you can refer to it when necessary. > Hand this documentation on to any subsequent users of the product.
2 Safety and the environment 2.2. Ensure safety > Do not operate the instrument if there are signs of damage at the housing, mains unit or feed lines. > Do not perform contact measurements on non-insulated, live parts. > Do not store the product together with solvents. Do not use any desiccants. > Carry out only the maintenance and repair work on this instrument that is described in the documentation. Follow the prescribed steps exactly. Use only original spare parts from Testo.
3 Specifications 2.2.3. Safety and the testo 805i • Laser radiation! Class 2 laser > Do not look into the laser beam! 2.3. Protecting the environment > Dispose of faulty rechargeable batteries/spent batteries in accordance with the valid legal specifications. > At the end of its useful life, send the product to the separate collection for electric and electronic devices (observe local regulations) or return the product to Testo for disposal.
4 Product description 4 Product description 4.1. Overview of Smart Probes 1 2 3 4 5 4.2. Measuring unit LED Key Battery compartment (at the back) Direction of flow testo 405i / testo 410i (not shown) (An arrow on the top of the housing displays the direction of flow in which the measuring instrument has been calibrated and which achieves the best measurement results. Please note the direction of flow during usage.
5 First steps 5 First steps 5.1. Switching on/off testo 549i 5.1.1. Switching on 1. Pull the film out of the battery compartment. 2. Press the button on your Smart Probe. - The Smart Probe switches on. 5.1.2. Switching off 1. Press and hold the button on your Smart Probe. - The Smart Probe switches off. 5.2. Establishing Bluetooth® connection You need a tablet or smartphone with the testo Smart Probes App already installed on it to be able to establish a Bluetooth connection.
6 Using the App 5.3. Transmitting readings ✓ The Smart Probe is switched on and connected to your mobile terminal device via Bluetooth. - The current readings are automatically displayed in the App. 6 Using the App 6.1. Overview of operating controls 1 10 Choice of applications. 2 3 Display of connected Smart Probes. Switch between the views (list, graphic diagram, table) 4 Measurement settings.
6 Using the App 6.2. App options 6.2.1. Set “Language” 1. 2. 3. - 6.2.2. Tap -> Settings -> Language. A selection list is displayed. Tap the required language. The selected language receives a green check mark. Tap ◄ several times until the measurement view is displayed. The language has been changed. Display Tutorial The Tutorial guides you through the first steps when operating the testo Smart Probes App. 1. Tap -> Tutorial - The Tutorial is displayed. In Tutorial, swipe to display the next page.
6 Using the App 6.3. Application menus 6.3.1. Selecting the application menu 1. 2. - Press . A selection of menus for various applications is displayed. Select the required application. The selection disappears and your selected application is displayed. 6.3.2. Setting favourites 1. Press . - A selection of applications is displayed. 2. Press next to the application that you would like to designate as a favourite.
6 Using the App 6.5. List, graphic diagram and table view The available readings can be displayed in different ways in the various views. • • • List view Displays the readings transmitted by the Smart Probe in the form of a list. Readings from all connected Smart Probes are displayed here. Graphic diagram view The graphical progression of up to four different readings can be displayed. Tap on a reading above the diagram to select the readings to be displayed.
6 Using the App 6.8. Exporting readings 6.8.1. Excel (CSV) Export 1. 2. - Press . A selection of export options appears. Press Export Excel (CSV). A list of readings is displayed. 3. Press . - A selection of sending/export options appears. 4. Select your required sending/export options. 6.8.2. PDF Export 1. 2. - Press . A selection of export options appears. Press Export PDF. A PDF is created and saved on your mobile terminal device (Android only) or sent via e-mail (iOS and Android). 3.
7 Maintaining the product 7 Maintaining the product 7.1. Maintaining Smart Probes Cleaning the instrument > Do not use any aggressive cleaning agents or solvents! > Mild household cleaning agents or soap suds may be used. > If the housing of the instrument is dirty, clean it with a damp cloth. Keeping connections clean > Keep connections clean and free of grease and other deposits, clean with a damp cloth as required.
8 Tips and assistance 8 Tips and assistance 8.1. Questions and answers Question Answer LED flashes red • • Batteries are almost spent. Change batteries. The instrument switches Remaining battery capacity insufficient itself off > Change the batteries. --- lights up instead of the measurement parameter display The App cannot be found in the store 8.2. • > or • > Outside the permissible measuring range. Keep within the permissible measuring range.
9 Technical data 9 Technical data 9.1. Bluetooth module The use of the wireless module is subject to the regulations and stipulations of the respective country of use, and the module may only be used in each case in countries for which a country certification has been granted. The user and every owner undertake to adhere to these regulations and prerequisites for use, and acknowledge that the re-sale, export, import, etc.
9 Technical data 9.2.2. testo 410i Feature Values Measuring range 0.4 to 30 m/s / 80 to 5,900 fpm -20 to 60 °C / -4 to 140 °F Accuracy ± 1 digit ± (0.2 m/s + 2% of m.v.) (0.4 to 20 m/s) ± (40 fpm + 2% of m.v.) (80 to 4,000 fpm) ± 0.5 °C / ±0.9 °F Resolution 0.1 °C / 0.1 °F 0.
9 Technical data Feature Values Measurement rate 1/sec Available units of measurement °C, °F, m/s, fpm, m³/h, cfm, l/s Storage temperature -20 °C to 60 °C / -4 to 140 °F Operating temperature -20 °C to +50 °C / -4 to 122 °F Battery type 3 micro batteries AAA Battery life 15 hrs Dimensions 200 mm × 30 mm × 41 mm Extendible telescope 400 mm Probe shaft diameter 12 mm Probe tip diameter 9 mm Directives, standards and tests EU guideline: 2014/30/EU 9.2.4.
9 Technical data 9.2.5. testo 805i Feature Values Measuring range -30 °C to 250 °C / -22 to 482 °F Accuracy ± 1 digit ± 1.5 °C or ± 1.5% of m.v. (0 to 250 °C) ± 2.0 °C (-20.0 to -0.1 °C) ± 2.5 °C (-30.0 to -20.1 °C) ± 2.7 °F or ± 1.5% of m.v. (32 to 482 °F) ± 3.6 °F (-4 to 32 °F) ± 4.5 °F (-22 to -4 °F) Resolution 0.1 °C / 0.
9 Technical data Feature Values Measurement rate 1/sec Available units of measurement °C, °F, %RH, °Ctd, °Ftd, wetbulb °C, wetbulb °F Storage temperature -20 °C to 60 °C / -4 to 140 °F Operating temperature -20 °C to +50 °C / -4 to 122 °F Battery type 3 micro batteries AAA Battery life 150 h Dimensions 243 mm × 30 mm × 24 mm Probe shaft length 100 mm Directives, standards and tests EU guideline: 2014/30/EU 9.2.7.
9 Technical data 9.2.8. testo 115i Feature Values Measuring range -40 to 150 °C / -58 to 302 °F Accuracy ± 1 digit ± 1.3 °C (-20 to 85 °C) ± 2.34 °F (-4 to 185 °F) Resolution 0.1 °C / 0.1 °F Measurement rate 1/sec Available units of measurement °C, °F Storage temperature -20 °C to 60 °C / -4 to 140 °F Operating temperature -20 °C to +50 °C / -4 to 122 °F Battery type 3 micro batteries AAA Battery life 150 h Dimensions 183 mm × 90 mm × 30 mm max.
10 Certifications 10 Certifications Product testo 115i, testo 405i, testo 410i, testo 510i, testo 549i, testo 605i, testo 805i, testo 905i Mat.-No. 0560 1115, 0560 1405, 0560 1410, 0560 1510, 0560 1549, 0560 1605, 0560 1805, 0560 1905 Country Comments E 1561 Australia Brazil “Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário.
10 Certifications China CMII ID: testo 115i CMIIT ID: 2015DP6557 testo 405i CMIIT ID: 2015DP6558 testo 410i CMIIT ID: 2015DP6612 testo 510i CMIIT ID: 2015DP6559 testo 549i CMIIT ID: 2015DP6560 testo 605i CMIIT ID: 2015DP6561 testo 805i CMIIT ID: 2015DP6562 testo 905i CMIIT ID: 2015DP6563 The EU Declaration of Conformity can be found on the testo homepage www.testo.com under the product specific downloads.
10 Certifications Japan testo 115i testo 405i testo 410i testo 510i testo 549i testo 605i testo 905i see Japan Information Korea testo 115i Certification No. MSIP-CRM-Toi-115i testo 405i Certification No. MSIP-CRM-Toi-405i testo 410i Certification No. MSIP-CRM-Toi-410i testo 510i Certification No. MSIP-CRM-Toi-510i testo 549i Certification No. MSIP-CRM-Toi-549i testo 605i Certification No. MSIP-CRM-Toi-605i testo 805i Certification No. MSIP-CRM-Toi-805i testo 905i Certification No.
10 Certifications Taiwan Turkey USA testo 115i NCC: CCAB16LP177FT0 testo 405i NCC: CCAB16LP177AT3 testo 410i NCC: CCAB16LP1770T1 testo 510i NCC: CCAB16LP177DT9 testo 549i NCC: CCAB16LP177ET1 testo 605i NCC: CCAB16LP177BT5 testo 805i NCC: CCAB16LP177CT7 testo 905i NCC: CCAB16LP177GT2 Authorized Product FCC ID: testo 115i FCC ID: 2ACVD-1115 testo 405i FCC ID: 2ACVD-1405 testo 410i FCC ID: 2ACVD-1410 testo 510i FCC ID: 2ACVD-1510 testo 549i FCC ID: 2ACVD-1549 testo 605i FCC ID: 2A
10 Certifications Bluetooth SIG List Bluetooth® Range 15 m (free field) (varies with the used mobile device) Bluetooth® type LSD Science & Technology Co., Ltd L Series BLE Module (08 Mai 2013) based on TI CC254X chip Qualified Design ID B016552 Bluetooth® radio class Class 3 Bluetooth® company ID 10274 IC Warnings This instrument complies with Part 15C of the FCC Rules and Industry Canada RSS-210 (revision 8).
10 Certifications • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Caution Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Shielded interface cable must be used in order to comply with the emission limits. Warning This device complies with Part 15 of the FCC Rules.
Testo SE & Co. KGaA Testo-Straße 1 79853 Lenzkirch Germany Tel.: +49 7653 681-0 Fax: +49 7653 681-7699 E-Mail: info@testo.de www.testo.