User's Manual

28
WiFi data logger t 160 THG t 160 IAQ t 160 E
Order number 0572 2025 0572 2014 0572 2022
Operating
temperature
-10 °C to 50 °C -10 °C to 50 °C -10 °C to 50 °C
Storage
temperature
-20 °C to 50 °C
Protection class IP20
Measuring cycle Depends on the Cloud licence
Basic: 150 min fixed / Advanced 1 min to 24 h flexible
Communication
cycle
Depends on the Cloud licence
Basic: 150 min fixed / Advanced 1 min to 24 h flexible
Memory 40,000 readings (sum of all channels)
4 x AAA batteries 1.5 V
Alternatively mains unit via USB connection
Voltage supply 4 x AAA batteries
1.5 V, alternatively
mains unit via
USB connection
4 x AA batteries
1.5 V, alternatively
mains unit via
USB connection
4 x AAA batteries
1.5 V, alternatively
mains unit via
USB connection
Battery life 12 months
Dimensions 64 x 76 x 72 mm 82 x 117 x 32 mm 64 x 76 x 22 mm
Weight including
batteries
94 g 269 g 94 g
4 Commissioning
4.1 Starting up the data logger
1 - Mount the wall bracket at the
designated location using suitable
mounting materials.
2 - Open battery compartment cover.
3 - Remove battery safety strip.