Brochure

testo 176 T4
Order no.: 0572 1764
testo 176 T4
TC (Types T , K and J)
4 x external
°C, °F
-200 to +400 °C (Type T)
-195 to +1000 °C (Type K)
-100 to +750 °C (Type J)
±1% of reading (-200 to 100.1 °C)
±0.3 °C (-100 to +70 °C)
±0.5% of m.v. (+70.1 to +1000 °C)
0.1 °C
8 years
at 15 min. meas. rate
-20 to +70 °C
-40 to +85 °C
103 x 63 x 33 mm
1 x Lithium (TLH-5903)
IP 54
1 sec - 24 h
2 mio. measurement values
ComSoft Basic 5
ComSoft Professional 4
ComSoft CFR 21 Part 11
testo 176 T4
testo 176 P1
testo 176 H2
testo 176 H1
4-channel temperature data logger
with external sensor connections
(TC Type T, Type K and Type J)
4-channel temperature and
humidity data logger with external
sensor connections
(NTC/capacitive humidity sensor)
4-channel temperature and humidity
data logger in metal housing with
external sensor connections
(NTC/capacitive humidity sensor)
5-channel pressure, temperature and humidity data
logger with internem sensor (absolute pressure)
and external sensor connections (NTC/capacitive
humidity sensor)
· Highly accurate and secure documentation of the
ambient conditions e. g. in a laboratory
· Internal absolute pressure sensor and connection
possibilities for two external humidity probes
· Parallel temperature measurement at
up to four measurement sites using
different connectable thermocouple
probes for different applications
· Easy monitoring and documentation,
e. g. of the flow and return temperatu-
re of an underfloor heating system at
up to four measurement sites simulta-
neously
· Parallel temperature and humidity
measurement
· Different connectable humidity and
temperature probes, e. g. for humi-
dity monitoring in storerooms
· Parallel temperature and humidity
measurement with various connec-
table humidiy and temperature pro-
bes for different applications
· Robust metal housing protects from
mechanical influences such as impact
testo 176 H2
Order no.: 0572 1766
testo 176 H2
NTC/ capacitive humidity sensor
2 probes, 4 external channels
°C, °F, %rF, %RH, td, g/m
3
, WB
-20 to +70 °C
-40 to +70 °C
td
0 to 100 %RH
±0.2 °C (-20 to +70 °C)
±0.4 °C (remaining meas. range)
0.1 °C, 0.1 %RH
8 years
at 15 min. meas. rate
-20 to +70 °C
-40 to +85 °C
103 x 63 x 33 mm
1 x Lithium (TLH-5903)
IP 65
1 sec - 24 h
2 mio. measurement values
ComSoft Basic 5
ComSoft Professional 4
ComSoft CFR 21 Part 11
testo 176 P1
NTC/ capacitive humidity sensor/ absolute pressure sensor
1 x internal, 2 probes, 4 external channels
°C , °F, %rF, %RH, td, g/m
3
, hPa, mbar, in Hg, in H20, psi
-20 to +70 °C
-40 to +70 °C
td
0 to 100 %RH / 600 mbar to 1100 mbar
±0.2 °C (-20 to +70 °C)
±0.4 °C (remaining measuring range)
±3 mbar (0 to 50 °C)
0.1 °C, 0.1 %RH, 1 mbar
8 years
at 15 min. meas. rate
-20 to +70 °C
-40 to +85 °C
103 x 63 x 33 mm
1 x Lithium (TLH-5903)
IP 54
1 sec - 24 h
2 mio. measurement values
ComSoft Basic 5
ComSoft Professional 4
ComSoft CFR 21 Part 11
testo 176 P2
Order no.: 0572 1767
testo 176 H1
Order no.: 0572 1765
testo 176 H1
NTC/ capacitive humidity sensor
2 probes, 4 external channels
°C, °F, %rF, %RH, td, g/m
3
, WB
-20 to +70 °C
-40 to +70 °C
td
0 to 100 %RH
±0.2 °C (-20 to +70 °C)
±0.4 °C (rest of measuring range)
0.1 °C, 0.1 %RH
8 years
at 15 min. meas. rate
-20 to +70 °C
-40 to +85 °C
103 x 63 x 33 mm
1 x Lithium (TLH-5903)
IP 65
1 sec - 24 h
2 mio. measurement values
ComSoft Basic 5
ComSoft Professional 4
ComSoft CFR 21 Part 11