Installation Instructions

9.3 Power Supply Connections
To power TMD MK5 FPT use the specific cable provided (code 3903929) with the device.
Do not connect the connector to TMD MK5 FPT until the entire system
is completed.
Use the cable with the loose wires.
Proceed as follows:
1.
Identify the red wire (+30 VBatt.), the yellow wire (15, ignition terminal) and the black wire
(ground).
2.
Draw power for the +30 VBatt line directly from the vehicle's battery.
It is MANDATORY to connect the yellow wire (+15 V key-on) only in
case of accessories such as the driver recognition device.
Make sure the +30 V and ground power supplies are correct in order
to avoid the arising of false alarms from the TMD MK5 FPT control
unit (discharged battery alarm, power disconnection alarm).
23