Datasheet


   
SCAS042B − MAY 1988 − REVISED APRIL 1996
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443
HOUSTON, TEXAS 77251−1443
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
−0.5 V to 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
(see Note 1) −0.5 V to V
CC
+ 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, V
O
(see Note 1) −0.5 V to V
CC
+ 0.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input clamp current, I
IK
(V
I
< 0 or V
I
> V
CC
) ±20 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output clamp current, I
OK
(V
O
< 0 or V
O
> V
CC
) ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, I
O
(V
O
= 0 to V
CC
) ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous current through V
CC
or GND ±200 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum power dissipation at T
A
= 55°C (in still air) (see Note 2): D package 1.3 W. . . . . . . . . . . . . . . . . . . .
N package 1.1 W. . . . . . . . . . . . . . . . . . . .
PW package 0.5 W. . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. The input and output voltage ratings may be exceeded if the input and output current ratings are observed.
2. The maximum package power dissipation is calculated using a junction temperature of 150_C and a board trace length of 750 mils,
except for the N package, which has a trace length of zero.
recommended operating conditions
MIN NOM MAX UNIT
V
CC
Supply voltage 3 5 5.5 V
V
CC
= 3 V 2.1
V
IH
High-level input voltage
V
CC
= 4.5 V
3.15
V
V
IH
High-level input voltage
V
CC
= 5.5 V 3.85
V
V
CC
= 3 V 0.9
V
IL
Low-level input voltage
V
CC
= 4.5 V
1.35
V
V
IL
Low-level input voltage
V
CC
= 5.5 V 1.65
V
V
I
Input voltage 0 V
CC
V
V
O
Output voltage 0 V
CC
V
V
CC
= 3 V −4
I
OH
High-level output current
V
CC
= 4.5 V
−24
mA
I
OH
High-level output current
V
CC
= 5.5 V −24
mA
V
CC
= 3 V 12
I
OL
Low-level output current
V
CC
= 4.5 V
24
mA
I
OL
Low-level output current
V
CC
= 5.5 V 24
mA
t/v Input transition rise or fall rate 0 10 ns/V
T
A
Operating free-air temperature −40 85 °C