Datasheet


   
SCAS042B − MAY 1988 − REVISED APRIL 1996
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
POST OFFICE BOX 1443
HOUSTON, TEXAS 77251−1443
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
TEST CONDITIONS
V
CC
T
A
= 25°C
MIN
MAX
UNIT
TEST CONDITIONS
V
CC
MIN TYP MAX
MIN
MAX
UNIT
3 V 2.9 2.9
I
OH
= −50 µA
4.5 V 4.4 4.4
I
OH
= −50 µA
5.5 V 5.4 5.4
V
I
OH
= −4 mA 3 V 2.58 2.48
V
I
OH
= −24 mA
4.5 V 3.94 3.8
V
I
OH
= −24 mA
5.5 V 4.94 4.8
I
OH
= −75 mA
5.5 V 3.85
3 V 0.1 0.1
I
OL
= 50 µA
4.5 V 0.1 0.1
I
OL
= 50 µA
5.5 V 0.1 0.1
V
I
OL
= 12 mA 3 V 0.36 0.44
V
I
OL
= 24 mA
4.5 V 0.36 0.44
V
I
OL
= 24 mA
5.5 V 0.36 0.44
I
OL
= 75 mA
5.5 V 1.65
I
I
V
I
= V
CC
or GND 5.5 V ±0.1 ±1 µA
I
CC
V
I
= V
CC
or GND, I
O
= 0 5.5 V 4 40 µA
C
i
V
I
= V
CC
or GND 5 V 3.5 pF
Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
switching characteristics over recommended operating free-air temperature range,
V
CC
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
FROM
TO
T
A
= 25°C
MIN
MAX
UNIT
FROM
(INPUT)
TO
(OUTPUT)
MIN TYP MAX
MIN
MAX
UNIT
t
PLH
A, B, C
Any Y
1.5 8.3 10.2 1.5 11.4
ns
t
PHL
A, B, C Any Y
1.5 8.9 10.9 1.5 12.2
ns
t
PLH
G1
Any Y
1.5 7.2 9.2 1.5 10.2
ns
t
PHL
G1 Any Y
1.5 7.3 9.4 1.5 10.5
ns
t
PLH
G2A, G2B
Any Y
1.5 8.2 10.4 1.5 11.5
ns
t
PHL
G2A, G2B
Any Y
1.5 8.3 10.4 1.5 11.6
ns
switching characteristics over recommended operating free-air temperature range,
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
FROM
TO
T
A
= 25°C
MIN
MAX
UNIT
FROM
(INPUT)
TO
(OUTPUT)
MIN TYP MAX
MIN
MAX
UNIT
t
PLH
A, B, C
Any Y
1.5 5.7 7.3 1.5 8.1
ns
t
PHL
A, B, C Any Y
1.5 6.2 7.9 1.5 8.8
ns
t
PLH
G1
Any Y
1.5 5.1 6.9 1.5 7.5
ns
t
PHL
G1 Any Y
1.5 5.2 6.9 1.5 7.7
ns
t
PLH
G2A, G2B
Any Y
1.5 5.8 7.6 1.5 8.3
ns
t
PHL
G2A, G2B
Any Y
1.5 5.6 7.5 1.5 8.3
ns