Datasheet

54AC16374, 74AC16374
16-BIT EDGE-TRIGGERED D-TYPE FLIP-FLOPS
WITH 3-STATE OUTPUTS
SCAS123B – MARCH 1990 – REVISED APRIL 1996
5
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
timing requirements over recommended operating free-air temperature range
V
CC
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
T
A
= 25°C 54AC16374 74AC16374
UNIT
MIN MAX MIN MAX MIN MAX
UNIT
f
clock
Clock frequency 0 60 0 60 0 60 MHz
t
w
Pulse duration CLK high or low 8.3 8.3 8.3 ns
t
su
Setup time, data before CLK 7.5 7.5 7.5 ns
t
h
Hold time, data after CLK 0 0 0 ns
timing requirements over recommended operating free-air temperature range
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
T
A
= 25°C 54AC16374 74AC16374
UNIT
MIN MAX MIN MAX MIN MAX
UNIT
f
clock
Clock frequency 0 100 0 100 0 100 MHz
t
w
Pulse duration CLK high or low 5 5 5 ns
t
su
Setup time, data before CLK 5 5 5 ns
t
h
Hold time, data after CLK 0 0 0 ns
switching characteristics over recommended operating free-air temperature range
V
CC
= 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM TO
T
A
= 25°C 54AC16374 74AC16374
UNIT
PARAMETER
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX MIN MAX
UNIT
f
max
60 60 60 MHz
t
PLH
CLK
Q
4.9 12.2 15 4.9 17 4.9 17
ns
t
PHL
CLK
Q
4.8 11.9 14.3 4.8 15.7 4.8 15.7
ns
t
PZH
OE
Q
4.3 11.9 14.7 4.3 16.8 4.3 16.8
ns
t
PZL
OE
Q
5.3 15.5 18.7 5.3 21.2 5.3 21.2
ns
t
PHZ
OE
Q
4 7.3 9 4 9.8 4 9.8
ns
t
PLZ
OE
Q
3.8 7.1 8.8 3.8 9.4 3.8 9.4
ns
switching characteristics over recommended operating free-air temperature range
V
CC
= 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM TO
T
A
= 25°C 54AC16374 74AC16374
UNIT
PARAMETER
(INPUT) (OUTPUT)
MIN TYP MAX MIN MAX MIN MAX
UNIT
f
max
100 100 100 MHz
t
PLH
CLK
Q
3.8 7.6 9.5 3.8 10.8 3.8 10.8
ns
t
PHL
CLK
Q
3.8 7.6 9.5 3.8 10.6 3.8 10.6
ns
t
PZH
OE
Q
3.2 7.2 9 3.2 10.2 3.2 10.2
ns
t
PZL
OE
Q
3.8 8.7 10.7 3.8 12.1 3.8 12.1
ns
t
PHZ
OE
Q
3.7 6 7.5 3.7 8.2 3.7 8.2
ns
t
PLZ
OE
Q
3.5 5.8 7.3 3.5 7.9 3.5 7.9
ns
operating characteristics, V
CC
= 5 V, T
A
= 25°C
PARAMETER TEST CONDITIONS TYP UNIT
C
d
p
p
p
p
p
Outputs enabled
C
L
=50
p
F
f=1MHz
49
p
F
C
pd
w
-
Outputs disabled
C
L
=
50
pF
,
f
=
1
MH
z
32
pF
PRODUCT PREVIEW information concerns products in the formative or
design phase of development. Characteristic data and other
specifications are design goals. Texas Instruments reserves the right to
change or discontinue these products without notice.