Datasheet

- 20 -
Copyright 2011 National Semiconductor Corporation
I-channel: This tab changes the sign and the magnitude of the offset and the full scale range
settings.
Figure 12: I-Channel Panel
I-channel Offset Sign – This pull-down selects a positive or negative offset.
I-ch Offset – This slider selects the magnitude of I-ch Offset applied. Adjustment can be
done using the computer mouse/pointer, or using left/right arrow keys once the slider
has been selected. Although the offset is entered in a 10 bit (0 to 4095) relative form, it is
also displayed in approximate mV.
I-Channel Full Scale - The approximate I-Channel input full scale range (mV peak-to-
peak) is selected, ranging from a minimum of 600mV to a maximum of 1000mV. The
default setting is 800mV.
Note: No changes will take effect until the Write I-ch Reg button is clicked. Also, the ADC must
be re-calibrated if the full-scale is changed.
Q-channel:
Similar to I-channel