Datasheet

- 25 -
Copyright 2011 National Semiconductor Corporation
Debug Tabs: These panels provide the actual register settings which are conveniently
formatted in the other tabs above. They may also be read to and written from and these
changes will be reflected in the corresponding tabs.
Figure 16: Debug Panel
Note: No changes will appear until the Read/Write button is clicked.
Special Note:
Register 6h must be programmed to 1C0Eh before calibrating for the
ADC12D1800RF to function properly. This is accomplished automatically via the GUI
programming for the ADC12D1800RF Reference Board, and in the customer’s system, it must
also be programmed.