Datasheet
Table Of Contents

www.ti.com
TIMING CHARACTERISTICS
(1) (2) (3) (4)
ADS8380
SLAS387A – NOVEMBER 2004 – REVISED DECEMBER 2004
ADS8380I/ADS8380IB
REF
PARAMETER UNIT
FIGURE
MIN TYP MAX
CONVERSION AND SAMPLING
t
d1
Delay time, conversion start command to conversion start (aperture delay) 10 ns 41,43
t
d2
Delay time, conversion end to BUSY fall 5 ns 41 – 43
t
d4
Delay time, conversion start command to BUSY rise 20 ns 41
t
d3
Delay time, CONVST rise to sample start 5 ns 43
t
d5
Delay time, CS fall to sample start 10 ns 43
t
d6
Delay time, conversion abort command to BUSY fall 10 ns 44
DATA READ OPERATION
t
d12
Delay time, CS fall to MSB valid 3 15 ns 45
t
d15
Delay time, FS rise to MSB valid 6 18 ns 46,47
t
d7
Delay time, BUSY fall to MSB valid (if FS is high when BUSY falls) 18 ns 47
t
d13
Delay time, SCLK rise to bit valid 2 10 ns 45– 47
t
d14
Delay time, CS rise to SDO 3-state 6 ns 45
MISCELLANEOUS
t
d10
Delay time, PD rise to SDO 3-state 55 ns 53,54
Nap mode 300 ns 55
Delay time, total Full power down (external reference used with or without t
d11
+ 2x
54
t
d18
device resume 1-µF||0.1-µF capacitor on REFOUT) conversions
time
Full power down (internal reference used with or without
25
(4)
ms 53
1-µF||0.1-µF capacitor on REFOUT)
t
d11
Delay time, untrimmed circuit full power-down resume time 1 ms 53,54
Delay time, device Nap 200 ns 55
t
d16
power-down time
Full power down (internal/external reference used) 10 µs 53,54
Delay time, trimmed internal reference settling (either by turning on supply or
t
d17
4 ms 53
resuming from full power-down mode), with 1-µF||0.1-µF capacitor on REFOUT
(1) All input signals are specified with t
r
= t
f
= 5 ns (10% to 90% of V
DD
) and timed from a voltage level of (V
IL
+ V
IH
)/2.
(2) All specifications typical at –40°C to 85°C, +VA = +4.75 V to +5.25 V, +VBD = +2.7 V to +5.25 V.
(3) All digital output signals loaded with 10-pF capacitors.
(4) Including t
d11
, two conversions (time to cycle CONVST twice), and t
d17
.
6
Submit Documentation Feedback