Datasheet
I C connector on TLV320AIC3262 stick EVM
2
1. SCL
2. SDA
3. GND
4. IOV
DD
Appendix A
SLAU448–June 2012
TLV320AIC3262 Stick EVM EEPROM
Image Programming Guide
1. Install the TotalPhaseUSB-v2.10 driver using TotalPhaseUSB-v2.10.exe. This driver installation file is
located at: \\vette02\dg_audio\USERS\Austin\software.
2. Open the Aardvark™ GUI by double-clicking on Aardvark GUI.exe. Aardvark GUI is located at:
\\vette02\dg_audio\USERS\Austin\software\aardvark-gui-windows-v3.53.
3. Setup the hardware.
• Build the I
2
C
®
(SDA, SCL, IOV
DD
, GND) connection between the Aardvark GUI and the
TLV320AIC3262 stick EVM.
SCL SDA NC + 5 V GND
Aardvark GUI 1 3 4 2
TLV320AIC3262 I
2
C connector 1 2 4 3
• Connect the Aardvark GUI to a PC through USB cable. Now the Aardvark GUI will be recognized
as the Total Phase Aardvark I
2
C/SPI Host Adaptor under the windows device manager.
4. Program the TUSB3200 firmware (\\vette02\dg_audio\USERS\Austin\software\TUSB3200 image)
• Open the Aardvark GUI and click Configure Aardvark Adaptor
• Highlight the Aardvark port and select Batch Mode, then click okay.
12
TLV320AIC3262 Stick EVM EEPROM Image Programming Guide SLAU448–June 2012
Submit Documentation Feedback