Datasheet

8
bq2002/F
Impedance
Symbol Parameter Minimum Typical Maximum Unit
R
BAT
Battery input impedance 50 - - M
R
TS
TS input impedance 50 - - M
Timing (T
A
= 0 to +70°C; V
CC
±
10%)
Symbol Parameter Minimum Typical Maximum Unit Notes
d
FCV
Base time variation -20 - 20 %
Note: Typical is at T
A
= 25°C, V
CC
= 5.0V.