7
bq2013H
PROG
4
Overload Threshold Display Mode
HV
OVLD
= -75mV Relative/4s timer after push-button release
ZV
OVLD
= -75mV Relative/4s timer after push-button release
LV
OVLD
= -25mV Absolute/4s timer after push-button release
Table 4. Programmed Display Mode
PROG
5
Trickle Fast
<30°C30°C—50°C >50°C <30°C30°C—50°C >50°C
H 0.80 0.75 0.70 0.95 0.90 0.85
Z 1.00 1.00 1.00 1.00 1.00 1.00
L 0.85 0.80 0.75 0.95 0.90 0.85
Table 5. Programmed Charge Compensation
PROG
6
Offset
H
-150µV
Z
-75µV
L
0µV
Table 6. Programmed Discharge Offset Adjustment